FabDigitFabDigit

Steel A514 Q&T vs A514-T5

Steel · A514 temper comparison

A514 Q&T and A514-T5 are two conditions of the same steel grade, A514: Q&T (quenched and tempered) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. A514 Q&T is the stronger of the two: yield strength 760 MPa (110 ksi) against 690 MPa (100 ksi) for A514-T5, about 10% more; tensile strength follows at 800 MPa (116 ksi) vs 760 MPa (110 ksi). A514 Q&T is harder — 250 HB against 235 HB for A514-T5 — which matters for wear surfaces and threads.

A514 Q&TChoose it when strength drives the design, or when surface hardness matters.

A514 Q&T vs A514-T5: properties

A514 Q&TA514-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

760 MPa110 ksi
690 MPa100 ksi

Elongation at Break

19%
20%

Reduction in Area

50%
52%

Compressive Strength

760 MPa110 ksi
690 MPa100 ksi

Shear Strength

480 MPa69.6 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
350 MPa50.8 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

75 J55.3 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

250 HB
235 HB

Hardness, Rockwell C

24 HRC
21 HRC

Hardness, Vickers

262 HV
247 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 100 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

42 W/m·K24.3 BTU/hr·ft·°F
43 W/m·K24.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -45°C-49 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7 % IACS · Electrical Resistivity 2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 16 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
42%

Weldability

55 / 100
57 / 100

Formability (cold)

30 / 100
33 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA514

A514 Q&T vs A514-T5 — frequently asked

Is A514 Q&T stronger than A514-T5?

Yes. A514 Q&T has a typical yield strength of 760 MPa (110 ksi) against 690 MPa (100 ksi) for A514-T5 — about 10% more. Tensile strength is 800 MPa (116 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, Q&T or T5?

Q&T is the default A514 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A514 Q&T over A514-T5?

Pick A514 Q&T when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A514 Q&T and A514-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.