Steel A232-CD vs A232-SR

Steel · A232 temper comparison

A232-CD and A232-SR are two conditions of the same steel grade, A232: CD (cold drawn) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. A232-SR is the stronger of the two: yield strength 1,620 MPa (235 ksi) against 980 MPa (142 ksi) for A232-CD, about 65% more; tensile strength follows at 1,780 MPa (258 ksi) vs 1,150 MPa (167 ksi). In exchange, A232-CD is the more ductile: elongation 8% versus 7% for A232-SR, and A232-SR is harder (505 HB vs 340 HB). A232-SR runs hotter in service (230°C vs 200°C continuous). On the shop floor, A232-CD machines more easily (fair vs poor) and A232-CD welds better (25 vs 15 out of 100).

A232-CDChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

A232-SRChoose it when strength drives the design, or when the part sees heat.

A232-CD vs A232-SR: properties

A232-CDA232-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

206 GPa29.9 Msi
207 GPa30 Msi

Tensile Strength (Ultimate)

1,150 MPa167 ksi
1,780 MPa258 ksi

Yield Strength (0.2% offset)

980 MPa142 ksi
1,620 MPa235 ksi

Elongation at Break

8%
7%

Reduction in Area

35%
38%

Shear Strength

690 MPa100 ksi
1,070 MPa155 ksi

Fatigue Strength (Endurance Limit)

480 MPa69.6 ksi
750 MPa109 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
43 MPa·√m39.1 ksi·√in

Hardness, Brinell

340 HB
505 HB

Hardness, Rockwell C

36 HRC
50 HRC

Hardness, Vickers

355 HV
530 HV

Same in both: Shear Modulus 79.3 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Charpy V-Notch Impact (RT) 12 J8.9 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
230°C446 °F

Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.5 % IACS · Electrical Resistivity 2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
18%

Weldability

25 / 100
15 / 100

Formability (cold)

35 / 100
20 / 100

Same in both: Brazeability / Solderability 30 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA232

A232-CD vs A232-SR — frequently asked

Is A232-SR stronger than A232-CD?

Yes. A232-SR has a typical yield strength of 1,620 MPa (235 ksi) against 980 MPa (142 ksi) for A232-CD — about 65% more. Tensile strength is 1,780 MPa (258 ksi) vs 1,150 MPa (167 ksi).

Which condition does FabDigit quote by default, CD or SR?

OT is the default A232 condition in the FabDigit quote flow (neither CD nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A232-CD or A232-SR?

A232-CD. Its machinability rates fair (38/100) against poor (18/100) for A232-SR; for welding the order is A232-CD first (poor, 25/100) then A232-SR (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in A232-CD and A232-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.