FabDigitFabDigit

Steel A2 vs L7

Steel · grade comparison

Steel A2 and L7 are both steel grades. A2 is the stronger of the two: yield strength 470 MPa (68.2 ksi) against 415 MPa (60.2 ksi) for L7, about 13% more. In exchange, L7 is the more ductile: elongation 25% versus 22% for A2, and A2 is harder (217 HB vs 195 HB). A2 runs hotter in service (425°C vs 250°C continuous) and L7 conducts heat better (35 W/m·K vs 26 W/m·K). On the shop floor, L7 sits in a lower cost tier (standard, $$) than A2 (premium, $$$).

A2Choose it when strength drives the design, or when the part sees heat.

L7Choose it when the part is bent, formed or impact-loaded, or when cost is the deciding factor.

A2 vs L7: properties

A2L7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

203 GPa29.4 Msi
207 GPa30 Msi

Shear Modulus

78 GPa11.3 Msi
80 GPa11.6 Msi

Poisson's Ratio

0.28
0.29

Tensile Strength (Ultimate)

740 MPa107 ksi
750 MPa109 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
415 MPa60.2 ksi

Elongation at Break

22%
25%

Compressive Strength

500 MPa72.5 ksi
430 MPa62.4 ksi

Shear Strength

450 MPa65.3 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
340 MPa49.3 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

217 HB
195 HB

Hardness, Rockwell B

96 HRB
92 HRB

Hardness, Vickers

230 HV
205 HV

Same in both: Bulk Modulus 160 GPa23.2 Msi · Reduction in Area 45%

Physical

Density and transition temperatures.

Density

7.86 g/cm³0.28 lb/in³
7.84 g/cm³0.28 lb/in³

Liquidus Temperature

1,465°C2,669 °F
1,470°C2,678 °F

Same in both: Melting Point (Solidus) 1,420°C2,588 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

26 W/m·K15 BTU/hr·ft·°F
35 W/m·K20.2 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

10.7 µm/m·K5.9 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Max Service Temperature (continuous)

425°C797 °F
250°C482 °F

Min Service Temperature

-30°C-22 °F
-60°C-76 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Latent Heat of Fusion 250 J/g107 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

2.7 % IACS
8 % IACS

Electrical Resistivity

6.5×10⁻⁷ Ω·m25.6 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

20 / 100
12 / 100

Galvanic Potential (seawater, vs SCE)

—
-0.62 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
45%

Weldability

20 / 100
15 / 100

Formability (cold)

35 / 100
25 / 100

Brazeability / Solderability

40 / 100
45 / 100

Same in both: Castability 20 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

36 MJ/kg15,477 BTU/lb
33 MJ/kg14,187 BTU/lb

Embodied Carbon (primary production)

2.6 kg CO₂/kg
2.4 kg CO₂/kg

Embodied Water

65 L/kg7.8 gal/lb
70 L/kg8.4 gal/lb

Typical Recycled Content

35%
30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

94 kN·m/kg
96 kN·m/kg

Specific Stiffness (E / density)

25.8 MN·m/kg
26.4 MN·m/kg

Modulus of Resilience

544 kJ/m³
416 kJ/m³

Thermal Diffusivity

7.2 mm²/s
9.7 mm²/s

Thermal Shock Resistance Index

9
11

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA2L7

Manufacturing and finishing

CapabilityA2L7
CNC machiningYes—
Default conditionAnnealed—
Relative cost$$$ Premium$$ Standard
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

A2 vs L7 — frequently asked

Is A2 stronger than L7?

Yes. A2 has a typical yield strength of 470 MPa (68.2 ksi) against 415 MPa (60.2 ksi) for L7 — about 13% more. Tensile strength is 740 MPa (107 ksi) vs 750 MPa (109 ksi).

Which is cheaper, A2 or L7?

L7 is the lower-cost material: it sits in the standard tier ($$) while A2 is premium ($$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which welds better, A2 or L7?

A2. Its weldability rates poor (20/100) against poor (15/100) for L7.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A2 and L7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.