FabDigitFabDigit

Steel A182 F1-A vs A182 F1 AS-FORGED

Steel · A182 F1 temper comparison

A182 F1-A and A182 F1 AS-FORGED are two conditions of the same steel grade, A182 F1: A (solution annealed) versus AS-FORGED (prior to final heat treatment). The chemistry is identical, so every difference below comes from the condition. A182 F1 AS-FORGED is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 300 MPa (43.5 ksi) for A182 F1-A, about 13% more; tensile strength follows at 560 MPa (81.2 ksi) vs 500 MPa (72.5 ksi). In exchange, A182 F1-A is the more ductile: elongation 31% versus 24% for A182 F1 AS-FORGED, and A182 F1 AS-FORGED is harder (175 HB vs 148 HB). A182 F1-A runs hotter in service (510°C vs 400°C continuous).

A182 F1-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A182 F1 AS-FORGEDChoose it when strength drives the design.

A182 F1-A vs A182 F1 AS-FORGED: properties

A182 F1-AA182 F1 AS-FORGED

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
340 MPa49.3 ksi

Elongation at Break

31%
24%

Reduction in Area

58%
45%

Compressive Strength

300 MPa43.5 ksi
345 MPa50 ksi

Shear Strength

320 MPa46.4 ksi
360 MPa52.2 ksi

Fatigue Strength (Endurance Limit)

225 MPa32.6 ksi
245 MPa35.5 ksi

Fracture Toughness (K_IC)

115 MPa·√m105 ksi·√in
80 MPa·√m72.8 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

148 HB
175 HB

Hardness, Rockwell B

79 HRB
88 HRB

Hardness, Vickers

155 HV
184 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
43 W/m·K24.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

510°C950 °F
400°C752 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.4 % IACS
8.2 % IACS

Electrical Resistivity

2.05×10⁻⁷ Ω·m8.07 µΩ·in
2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
54 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Weldability

68 / 100
60 / 100

Formability (cold)

62 / 100
48 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA182 F1

A182 F1-A vs A182 F1 AS-FORGED — frequently asked

Is A182 F1 AS-FORGED stronger than A182 F1-A?

Yes. A182 F1 AS-FORGED has a typical yield strength of 340 MPa (49.3 ksi) against 300 MPa (43.5 ksi) for A182 F1-A — about 13% more. Tensile strength is 560 MPa (81.2 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, A or AS-FORGED?

N+T is the default A182 F1 condition in the FabDigit quote flow (neither A nor AS-FORGED). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A182 F1-A or A182 F1 AS-FORGED?

A182 F1-A. Its machinability rates good (62/100) against fair (54/100) for A182 F1 AS-FORGED; for welding the order is A182 F1-A first (good, 68/100) then A182 F1 AS-FORGED (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in A182 F1-A and A182 F1 AS-FORGED side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.