FabDigitFabDigit

Steel 8MnSi7 +A vs 8MnSi7 +U

Steel · 8MnSi7 temper comparison

8MnSi7 +A and 8MnSi7 +U are two conditions of the same steel grade, 8MnSi7: +A (annealed) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 8MnSi7 +U is the stronger of the two: yield strength 290 MPa (42.1 ksi) against 255 MPa (37 ksi) for 8MnSi7 +A, about 14% more; tensile strength follows at 450 MPa (65.3 ksi) vs 410 MPa (59.5 ksi). In exchange, 8MnSi7 +A is the more ductile: elongation 29% versus 23% for 8MnSi7 +U, and 8MnSi7 +U is harder (135 HB vs 122 HB).

8MnSi7 +AChoose it when the part is bent, formed or impact-loaded.

8MnSi7 +UChoose it when strength drives the design.

8MnSi7 +A vs 8MnSi7 +U: properties

8MnSi7 +A8MnSi7 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

410 MPa59.5 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
290 MPa42.1 ksi

Elongation at Break

29%
23%

Reduction in Area

68%
62%

Shear Strength

340 MPa49.3 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
210 MPa30.5 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

122 HB
135 HB

Hardness, Rockwell B

68 HRB
74 HRB

Hardness, Vickers

128 HV
142 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 490 MPa71.1 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,490°C2,714 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

48%
52%

Formability (cold)

92 / 100
80 / 100

Same in both: Weldability 85 / 100 · Castability 40 / 100 · Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale8MnSi7

8MnSi7 +A vs 8MnSi7 +U — frequently asked

Is 8MnSi7 +U stronger than 8MnSi7 +A?

Yes. 8MnSi7 +U has a typical yield strength of 290 MPa (42.1 ksi) against 255 MPa (37 ksi) for 8MnSi7 +A — about 14% more. Tensile strength is 450 MPa (65.3 ksi) vs 410 MPa (59.5 ksi).

Which condition does FabDigit quote by default, +A or +U?

+U+C is the default 8MnSi7 condition in the FabDigit quote flow (neither +A nor +U). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8MnSi7 +A or 8MnSi7 +U?

8MnSi7 +U, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 8MnSi7 +A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8MnSi7 +A and 8MnSi7 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.