FabDigitFabDigit

Steel 8620 Annealed vs 8620 Normalized

Steel · 8620 temper comparison

8620 Annealed and 8620 Normalized are two conditions of the same steel grade, 8620: Annealed versus Normalized. The chemistry is identical, so every difference below comes from the condition. 8620 Annealed is the stronger of the two: yield strength 385 MPa (55.8 ksi) against 360 MPa (52.2 ksi) for 8620 Normalized, about 7% more. 8620 Annealed is the more ductile: elongation 31% versus 26% for 8620 Normalized, and 8620 Normalized is harder (183 HB vs 149 HB).

8620 AnnealedChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

8620 Annealed vs 8620 Normalized: properties

8620 Annealed8620 Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

540 MPa78.3 ksi
630 MPa91.4 ksi

Yield Strength (0.2% offset)

385 MPa55.8 ksi
360 MPa52.2 ksi

Elongation at Break

31%
26%

Reduction in Area

62%
60%

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
300 MPa43.5 ksi

Fracture Toughness (K_IC)

85 MPa·√m77.4 ksi·√in
90 MPa·√m81.9 ksi·√in

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

149 HB
183 HB

Hardness, Rockwell B

80 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 390 MPa56.6 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46.6 W/m·K26.9 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.6 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
65%

Weldability

60 / 100
62 / 100

Formability (cold)

65 / 100
55 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale8620

8620 Annealed vs 8620 Normalized — frequently asked

Is 8620 Annealed stronger than 8620 Normalized?

Yes. 8620 Annealed has a typical yield strength of 385 MPa (55.8 ksi) against 360 MPa (52.2 ksi) for 8620 Normalized — about 7% more. Tensile strength is 540 MPa (78.3 ksi) vs 630 MPa (91.4 ksi).

Which condition does FabDigit quote by default, Annealed or Normalized?

HR is the default 8620 condition in the FabDigit quote flow (neither Annealed nor Normalized). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8620 Annealed or 8620 Normalized?

8620 Annealed, by a small margin. Both rate good for machinability — 68/100 against 62/100 for 8620 Normalized.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8620 Annealed and 8620 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.