FabDigitFabDigit

Steel 826M40 Normalized vs 826M40-V

Steel · 826M40 temper comparison

826M40 Normalized and 826M40-V are two conditions of the same steel grade, 826M40: Normalized versus V (hardened and tempered, 1000–1150 MPa). The chemistry is identical, so every difference below comes from the condition. 826M40-V is the stronger of the two: yield strength 900 MPa (131 ksi) against 620 MPa (89.9 ksi) for 826M40 Normalized, about 45% more; tensile strength follows at 1,075 MPa (156 ksi) vs 950 MPa (138 ksi). In exchange, 826M40 Normalized is the more ductile: elongation 16% versus 14% for 826M40-V, and 826M40-V is harder (320 HB vs 285 HB). On the shop floor, 826M40 Normalized welds better (30 vs 20 out of 100).

826M40 NormalizedChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

826M40-VChoose it when strength drives the design.

826M40 Normalized vs 826M40-V: properties

826M40 Normalized826M40-V

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

950 MPa138 ksi
1,075 MPa156 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
900 MPa131 ksi

Elongation at Break

16%
14%

Reduction in Area

45%
50%

Compressive Strength

630 MPa91.4 ksi
915 MPa133 ksi

Shear Strength

580 MPa84.1 ksi
645 MPa93.5 ksi

Fatigue Strength (Endurance Limit)

430 MPa62.4 ksi
510 MPa74 ksi

Fracture Toughness (K_IC)

70 MPa·√m63.7 ksi·√in
90 MPa·√m81.9 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
42 J31 ft·lbf

Hardness, Brinell

285 HB
320 HB

Hardness, Rockwell C

30 HRC
34 HRC

Hardness, Vickers

300 HV
336 HV

Same in both: Elastic (Young's) Modulus 208 GPa30.2 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.4 % IACS
7.2 % IACS

Electrical Resistivity

2.33×10⁻⁷ Ω·m9.17 µΩ·in
2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
38%

Weldability

30 / 100
20 / 100

Formability (cold)

25 / 100
18 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 50 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 33 MJ/kg14,187 BTU/lb · Embodied Carbon (primary production) 2.5 kg CO₂/kg · Embodied Water 75 L/kg9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale826M40

826M40 Normalized vs 826M40-V — frequently asked

Is 826M40-V stronger than 826M40 Normalized?

Yes. 826M40-V has a typical yield strength of 900 MPa (131 ksi) against 620 MPa (89.9 ksi) for 826M40 Normalized — about 45% more. Tensile strength is 1,075 MPa (156 ksi) vs 950 MPa (138 ksi).

Which condition does FabDigit quote by default, Normalized or V?

T is the default 826M40 condition in the FabDigit quote flow (neither Normalized nor V). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 826M40 Normalized or 826M40-V?

826M40 Normalized, by a small margin. Both rate fair for machinability — 45/100 against 38/100 for 826M40-V; for welding the order is 826M40 Normalized first (poor, 30/100) then 826M40-V (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 826M40 Normalized and 826M40-V side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.