FabDigitFabDigit

Steel 718 Annealed vs 718 Q&T-40

Steel · 718 temper comparison

718 Annealed and 718 Q&T-40 are two conditions of the same steel grade, 718: Annealed versus Q&T-40 (Q&T 38–44 HRC). The chemistry is identical, so every difference below comes from the condition. 718 Q&T-40 is the stronger of the two: yield strength 1,150 MPa (167 ksi) against 450 MPa (65.3 ksi) for 718 Annealed, about 156% more; tensile strength follows at 1,350 MPa (196 ksi) vs 700 MPa (102 ksi). In exchange, 718 Annealed is the more ductile: elongation 20% versus 10% for 718 Q&T-40, and 718 Q&T-40 is harder (390 HB vs 215 HB). 718 Annealed runs hotter in service (400°C vs 350°C continuous). On the shop floor, 718 Annealed machines more easily (good vs fair) and 718 Annealed welds better (good vs poor).

718 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

718 Q&T-40Choose it when strength drives the design.

718 Annealed vs 718 Q&T-40: properties

718 Annealed718 Q&T-40

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
1,350 MPa196 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
1,150 MPa167 ksi

Elongation at Break

20%
10%

Reduction in Area

45%
35%

Compressive Strength

900 MPa131 ksi
1,200 MPa174 ksi

Shear Strength

620 MPa89.9 ksi
810 MPa117 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
600 MPa87 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

215 HB
390 HB

Hardness, Rockwell C

32 HRC
41 HRC

Hardness, Vickers

325 HV
400 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

32 W/m·K18.5 BTU/hr·ft·°F
30 W/m·K17.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.6 µm/m·K7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 15 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
38%

Weldability

55 / 100
25 / 100

Formability (cold)

15 / 100
5 / 100

Polishability

55 / 100
80 / 100

Same in both: Brazeability / Solderability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale718

718 Annealed vs 718 Q&T-40 — frequently asked

Is 718 Q&T-40 stronger than 718 Annealed?

Yes. 718 Q&T-40 has a typical yield strength of 1,150 MPa (167 ksi) against 450 MPa (65.3 ksi) for 718 Annealed — about 156% more. Tensile strength is 1,350 MPa (196 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, Annealed or Q&T-40?

Prehard is the default 718 condition in the FabDigit quote flow (neither Annealed nor Q&T-40). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 718 Annealed or 718 Q&T-40?

718 Annealed. Its machinability rates good (68/100) against fair (35/100) for 718 Q&T-40; for welding the order is 718 Annealed first (good, 55/100) then 718 Q&T-40 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 718 Annealed and 718 Q&T-40 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.