FabDigitFabDigit

Steel 5160 vs 6120

Steel · grade comparison

Steel 5160 and 6120 are both steel grades. 6120 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 275 MPa (39.9 ksi) for 5160, about 35% more. 6120 is the more ductile: elongation 29% versus 17% for 5160, and 5160 is harder (197 HB vs 163 HB). 6120 runs hotter in service (425°C vs 250°C continuous). On the shop floor, 6120 welds better (good vs poor) and 6120 sits in a lower cost tier (budget, $) than 5160 (premium, $$$).

6120Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

5160 vs 6120: properties

51606120

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
370 MPa53.7 ksi

Elongation at Break

17%
29%

Reduction in Area

31%
58%

Shear Strength

450 MPa65.3 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

197 HB
163 HB

Hardness, Rockwell B

92 HRB
84 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,425°C2,597 °F
1,420°C2,588 °F

Liquidus Temperature

1,490°C2,714 °F
1,500°C2,732 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Specific Heat Capacity

490 J/kg·K0.12 BTU/lb·°F
475 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.3 µm/m·K6.8 µin/in·°F
12.2 µm/m·K6.8 µin/in·°F

Max Service Temperature (continuous)

250°C482 °F
425°C797 °F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
7.5 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

10 / 100
12 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

56%
60%

Weldability

25 / 100
55 / 100

Formability (cold)

45 / 100
58 / 100

Castability

40 / 100
—

Brazeability / Solderability

55 / 100
65 / 100

Polishability

70 / 100
60 / 100

Sustainability

Primary-production footprint per kilogram.

Typical Recycled Content

35%
30%

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

92 kN·m/kg
73 kN·m/kg

Modulus of Resilience

184 kJ/m³
334 kJ/m³

Thermal Diffusivity

12 mm²/s
11.8 mm²/s

Thermal Shock Resistance Index

13
10

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale51606120

Manufacturing and finishing

Capability51606120
CNC machiningYes—
Sheet metalYes—
Default conditionAnnealed—
Relative cost$$$ Premium$ Budget
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

5160 vs 6120 — frequently asked

Is 6120 stronger than 5160?

Yes. 6120 has a typical yield strength of 370 MPa (53.7 ksi) against 275 MPa (39.9 ksi) for 5160 — about 35% more. Tensile strength is 570 MPa (82.7 ksi) vs 725 MPa (105 ksi).

Which is cheaper, 5160 or 6120?

6120 is the lower-cost material: it sits in the budget tier ($) while 5160 is premium ($$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which welds better, 5160 or 6120?

6120. Its weldability rates good (55/100) against poor (25/100) for 5160.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5160 and 6120 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.