FabDigitFabDigit

Steel 5147-CD vs 5147-IH

Steel · 5147 temper comparison

5147-CD and 5147-IH are two conditions of the same steel grade, 5147: CD (cold drawn) versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. 5147-IH is the stronger of the two: yield strength 1,000 MPa (145 ksi) against 700 MPa (102 ksi) for 5147-CD, about 43% more; tensile strength follows at 1,150 MPa (167 ksi) vs 830 MPa (120 ksi). 5147-IH is harder — 600 HB against 248 HB for 5147-CD — which matters for wear surfaces and threads. 5147-CD runs hotter in service (350°C vs 200°C continuous). On the shop floor, 5147-CD machines more easily (good vs not recommended), 5147-CD welds better (poor vs not recommended), and 5147-CD forms better (poor vs not recommended).

5147-CDChoose it when the part sees heat, or when the part is machined in volume.

5147-IHChoose it when strength drives the design, or when surface hardness matters.

5147-CD vs 5147-IH: properties

5147-CD5147-IH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

830 MPa120 ksi
1,150 MPa167 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
1,000 MPa145 ksi

Reduction in Area

35%
42%

Compressive Strength

720 MPa104 ksi
1,050 MPa152 ksi

Shear Strength

500 MPa72.5 ksi
690 MPa100 ksi

Fatigue Strength (Endurance Limit)

385 MPa55.8 ksi
620 MPa89.9 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
50 MPa·√m45.5 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
16 J11.8 ft·lbf

Hardness, Brinell

248 HB
600 HB

Hardness, Vickers

261 HV
650 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 12% · Hardness, Rockwell B 92 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
200°C392 °F

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.5 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
7.5 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

57 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
12%

Weldability

30 / 100
8 / 100

Formability (cold)

25 / 100
5 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale5147

5147-CD vs 5147-IH — frequently asked

Is 5147-IH stronger than 5147-CD?

Yes. 5147-IH has a typical yield strength of 1,000 MPa (145 ksi) against 700 MPa (102 ksi) for 5147-CD — about 43% more. Tensile strength is 1,150 MPa (167 ksi) vs 830 MPa (120 ksi).

Which condition does FabDigit quote by default, CD or IH?

A is the default 5147 condition in the FabDigit quote flow (neither CD nor IH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5147-CD or 5147-IH?

5147-CD. Its machinability rates good (57/100) against not recommended (12/100) for 5147-IH; for welding the order is 5147-CD first (poor, 30/100) then 5147-IH (not recommended, 8/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5147-CD and 5147-IH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.