Steel 5147-CD vs 5147-IH
Steel · 5147 temper comparison
5147-CD and 5147-IH are two conditions of the same steel grade, 5147: CD (cold drawn) versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. 5147-IH is the stronger of the two: yield strength 1,000 MPa (145 ksi) against 700 MPa (102 ksi) for 5147-CD, about 43% more; tensile strength follows at 1,150 MPa (167 ksi) vs 830 MPa (120 ksi). 5147-IH is harder — 600 HB against 248 HB for 5147-CD — which matters for wear surfaces and threads. 5147-CD runs hotter in service (350°C vs 200°C continuous). On the shop floor, 5147-CD machines more easily (good vs not recommended), 5147-CD welds better (poor vs not recommended), and 5147-CD forms better (poor vs not recommended).
5147-CDChoose it when the part sees heat, or when the part is machined in volume.
5147-IHChoose it when strength drives the design, or when surface hardness matters.
5147-CD vs 5147-IH: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 12% · Hardness, Rockwell B 92 HRB
Physical
Density and transition temperatures.
Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.5 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
5147-CD vs 5147-IH — frequently asked
Is 5147-IH stronger than 5147-CD?
Yes. 5147-IH has a typical yield strength of 1,000 MPa (145 ksi) against 700 MPa (102 ksi) for 5147-CD — about 43% more. Tensile strength is 1,150 MPa (167 ksi) vs 830 MPa (120 ksi).
Which condition does FabDigit quote by default, CD or IH?
A is the default 5147 condition in the FabDigit quote flow (neither CD nor IH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, 5147-CD or 5147-IH?
5147-CD. Its machinability rates good (57/100) against not recommended (12/100) for 5147-IH; for welding the order is 5147-CD first (poor, 30/100) then 5147-IH (not recommended, 8/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in 5147-CD and 5147-IH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.