Steel 5132 and 5160 are both steel grades. 5132 is the stronger of the two: yield strength 385 MPa (55.8 ksi) against 275 MPa (39.9 ksi) for 5160, about 40% more. 5132 is the more ductile: elongation 22% versus 17% for 5160, and 5160 is harder (197 HB vs 174 HB). 5132 runs hotter in service (400°C vs 250°C continuous). On the shop floor, 5132 welds better (fair vs poor) and 5132 sits in a lower cost tier (budget, $) than 5160 (premium, $$$).

5132Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

5132 vs 5160: properties

51325160

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
725 MPa105 ksi

Yield Strength (0.2% offset)

385 MPa55.8 ksi
275 MPa39.9 ksi

Elongation at Break

22%
17%

Reduction in Area

55%
31%

Compressive Strength

385 MPa55.8 ksi
—

Shear Strength

400 MPa58 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
330 MPa47.9 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
—

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

174 HB
197 HB

Hardness, Rockwell B

88 HRB
92 HRB

Hardness, Vickers

183 HV
—

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Liquidus Temperature

1,500°C2,732 °F
1,490°C2,714 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
46 W/m·K26.6 BTU/hr·ft·°F

Specific Heat Capacity

475 J/kg·K0.11 BTU/lb·°F
490 J/kg·K0.12 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.2 µm/m·K6.8 µin/in·°F
12.3 µm/m·K6.8 µin/in·°F

Max Service Temperature (continuous)

400°C752 °F
250°C482 °F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

12 / 100
10 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
56%

Weldability

45 / 100
25 / 100

Formability (cold)

55 / 100
45 / 100

Castability

30 / 100
40 / 100

Brazeability / Solderability

60 / 100
55 / 100

Polishability

60 / 100
70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

2.1 kg CO₂/kg
2.2 kg CO₂/kg

Embodied Water

45 L/kg5.4 gal/lb
60 L/kg7.2 gal/lb

Typical Recycled Content

30%
35%

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

76 kN·m/kg
92 kN·m/kg

Modulus of Resilience

362 kJ/m³
184 kJ/m³

Thermal Diffusivity

11.8 mm²/s
12 mm²/s

Thermal Shock Resistance Index

11
13

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale51605132

Manufacturing and finishing

Capability51325160
CNC machining—Yes
Sheet metal—Yes
Default condition—Annealed
Relative cost$ Budget$$$ Premium
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

5132 vs 5160 — frequently asked

Is 5132 stronger than 5160?

Yes. 5132 has a typical yield strength of 385 MPa (55.8 ksi) against 275 MPa (39.9 ksi) for 5160 — about 40% more. Tensile strength is 600 MPa (87 ksi) vs 725 MPa (105 ksi).

Which is cheaper, 5132 or 5160?

5132 is the lower-cost material: it sits in the budget tier ($) while 5160 is premium ($$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 5132 or 5160?

5132, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 5160; for welding the order is 5132 first (fair, 45/100) then 5160 (poor, 25/100).