FabDigitFabDigit

Steel 5132-CD vs 5132-HR

Steel · 5132 temper comparison

5132-CD and 5132-HR are two conditions of the same steel grade, 5132: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 5132-CD is the stronger of the two: yield strength 660 MPa (95.7 ksi) against 425 MPa (61.6 ksi) for 5132-HR, about 55% more; tensile strength follows at 760 MPa (110 ksi) vs 690 MPa (100 ksi). In exchange, 5132-HR is the more ductile: elongation 19% versus 13% for 5132-CD, and 5132-CD is harder (223 HB vs 200 HB).

5132-CDChoose it when strength drives the design.

5132-HRChoose it when the part is bent, formed or impact-loaded.

5132-CD vs 5132-HR: properties

5132-CD5132-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

660 MPa95.7 ksi
425 MPa61.6 ksi

Elongation at Break

13%
19%

Reduction in Area

45%
48%

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

223 HB
200 HB

Hardness, Rockwell B

97 HRB
93 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 385 MPa55.8 ksi · Shear Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 75 MPa·√m68.3 ksi·√in · Hardness, Vickers 183 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

66 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
60%

Formability (cold)

35 / 100
55 / 100

Same in both: Weldability 45 / 100 · Castability 30 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale5132

5132-CD vs 5132-HR — frequently asked

Is 5132-CD stronger than 5132-HR?

Yes. 5132-CD has a typical yield strength of 660 MPa (95.7 ksi) against 425 MPa (61.6 ksi) for 5132-HR — about 55% more. Tensile strength is 760 MPa (110 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, CD or HR?

A is the default 5132 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5132-CD or 5132-HR?

5132-CD, by a small margin. Both rate good for machinability — 66/100 against 58/100 for 5132-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5132-CD and 5132-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.