FabDigitFabDigit

Steel 5120 vs 8640

Steel · grade comparison

Steel 5120 and 8640 are both steel grades. 8640 is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 295 MPa (42.8 ksi) for 5120, about 93% more; tensile strength follows at 860 MPa (125 ksi) vs 470 MPa (68.2 ksi). In exchange, 5120 is the more ductile: elongation 25% versus 19% for 8640, and 8640 is harder (229 HB vs 145 HB). 8640 runs hotter in service (400°C vs 350°C continuous). On the shop floor, 5120 welds better (good vs fair).

5120Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

8640Choose it when strength drives the design, or when the part sees heat.

5120 vs 8640: properties

51208640

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
860 MPa125 ksi

Yield Strength (0.2% offset)

295 MPa42.8 ksi
570 MPa82.7 ksi

Elongation at Break

25%
19%

Reduction in Area

55%
48%

Compressive Strength

295 MPa42.8 ksi
570 MPa82.7 ksi

Shear Strength

300 MPa43.5 ksi
520 MPa75.4 ksi

Fatigue Strength (Endurance Limit)

235 MPa34.1 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
80 MPa·√m72.8 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

145 HB
229 HB

Hardness, Rockwell B

78 HRB
—

Hardness, Vickers

152 HV
240 HV

Hardness, Rockwell C

—
20 HRC

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Specific Heat Capacity

470 J/kg·K0.11 BTU/lb·°F
475 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.9 µm/m·K6.6 µin/in·°F
12.2 µm/m·K6.8 µin/in·°F

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Min Service Temperature

-30°C-22 °F
-40°C-40 °F

Same in both: Latent Heat of Fusion 270 J/g116 BTU/lb

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.61 V
-0.65 V

Corrosion Resistance

12 / 100
14 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
60%

Weldability

60 / 100
40 / 100

Formability (cold)

58 / 100
35 / 100

Brazeability / Solderability

70 / 100
55 / 100

Polishability

55 / 100
60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

60 kN·m/kg
110 kN·m/kg

Modulus of Resilience

212 kJ/m³
792 kJ/m³

Thermal Diffusivity

12.5 mm²/s
12.1 mm²/s

Thermal Shock Resistance Index

9
15

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale51208640

Manufacturing and finishing

Capability51208640
Default conditionHRHR
Relative cost$$ Standard$$ Standard
Min. machined wall0.8 mm0.8 mm
Best machined surfaceRa 1.6 µmRa 1.6 µm

Both are offered for CNC machining and Sheet metal. Both take the same 38 finishes: AlCrN, AlTiN, Black Oxide, CVD Al2O3, CVD TiCN, CVD TiN, Cerakote, Chrome Plating, Copper Plating, CrN, DLC, E-Coating and 26 more.

5120 vs 8640 — frequently asked

Is 8640 stronger than 5120?

Yes. 8640 has a typical yield strength of 570 MPa (82.7 ksi) against 295 MPa (42.8 ksi) for 5120 — about 93% more. Tensile strength is 860 MPa (125 ksi) vs 470 MPa (68.2 ksi).

Which is cheaper, 5120 or 8640?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 5120 or 8640?

5120, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 8640; for welding the order is 5120 first (good, 60/100) then 8640 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5120 and 8640 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.