5120 Annealed and 5120-CD are two conditions of the same steel grade, 5120: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 5120-CD is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 280 MPa (40.6 ksi) for 5120 Annealed, about 71% more; tensile strength follows at 570 MPa (82.7 ksi) vs 450 MPa (65.3 ksi). In exchange, 5120 Annealed is the more ductile: elongation 28% versus 15% for 5120-CD, and 5120-CD is harder (170 HB vs 131 HB). 5120 Annealed runs hotter in service (400°C vs 300°C continuous). On the shop floor, 5120 Annealed welds better (65 vs 55 out of 100).

5120 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5120-CDChoose it when strength drives the design.

5120 Annealed vs 5120-CD: properties

5120 Annealed5120-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

280 MPa40.6 ksi
480 MPa69.6 ksi

Elongation at Break

28%
15%

Reduction in Area

60%
45%

Compressive Strength

280 MPa40.6 ksi
480 MPa69.6 ksi

Shear Strength

290 MPa42.1 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

225 MPa32.6 ksi
270 MPa39.2 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
80 MPa·√m72.8 ksi·√in

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

131 HB
170 HB

Hardness, Rockwell B

72 HRB
87 HRB

Hardness, Vickers

137 HV
178 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.9 % IACS
7.8 % IACS

Electrical Resistivity

2.18×10⁻⁷ Ω·m8.58 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
67 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
70%

Weldability

65 / 100
55 / 100

Formability (cold)

68 / 100
45 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale5120

5120 Annealed vs 5120-CD — frequently asked

Is 5120-CD stronger than 5120 Annealed?

Yes. 5120-CD has a typical yield strength of 480 MPa (69.6 ksi) against 280 MPa (40.6 ksi) for 5120 Annealed — about 71% more. Tensile strength is 570 MPa (82.7 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

HR is the default 5120 condition in the FabDigit quote flow (neither Annealed nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5120 Annealed or 5120-CD?

5120-CD, by a small margin. Both rate good for machinability — 67/100 against 60/100 for 5120 Annealed; for welding the order is 5120 Annealed first (good, 65/100) then 5120-CD (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5120 Annealed and 5120-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.