FabDigitFabDigit

Steel 4718-CD vs 4718-HR

Steel · 4718 temper comparison

4718-CD and 4718-HR are two conditions of the same steel grade, 4718: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 4718-CD is the stronger of the two: yield strength 640 MPa (92.8 ksi) against 460 MPa (66.7 ksi) for 4718-HR, about 39% more; tensile strength follows at 760 MPa (110 ksi) vs 700 MPa (102 ksi). In exchange, 4718-HR is the more ductile: elongation 22% versus 15% for 4718-CD, and 4718-CD is harder (229 HB vs 207 HB).

4718-CDChoose it when strength drives the design.

4718-HRChoose it when the part is bent, formed or impact-loaded.

4718-CD vs 4718-HR: properties

4718-CD4718-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

640 MPa92.8 ksi
460 MPa66.7 ksi

Elongation at Break

15%
22%

Reduction in Area

45%
50%

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
330 MPa47.9 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

229 HB
207 HB

Hardness, Rockwell B

98 HRB
94 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 380 MPa55.1 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
58%

Formability (cold)

35 / 100
45 / 100

Same in both: Weldability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4718

4718-CD vs 4718-HR — frequently asked

Is 4718-CD stronger than 4718-HR?

Yes. 4718-CD has a typical yield strength of 640 MPa (92.8 ksi) against 460 MPa (66.7 ksi) for 4718-HR — about 39% more. Tensile strength is 760 MPa (110 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, CD or HR?

A is the default 4718 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4718-CD or 4718-HR?

4718-CD. Its machinability rates good (58/100) against fair (50/100) for 4718-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4718-CD and 4718-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.