FabDigitFabDigit

Steel 4718-A vs 4718-CD

Steel · 4718 temper comparison

4718-A and 4718-CD are two conditions of the same steel grade, 4718: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 4718-CD is the stronger of the two: yield strength 640 MPa (92.8 ksi) against 400 MPa (58 ksi) for 4718-A, about 60% more; tensile strength follows at 760 MPa (110 ksi) vs 585 MPa (84.8 ksi). In exchange, 4718-A is the more ductile: elongation 27% versus 15% for 4718-CD, and 4718-CD is harder (229 HB vs 170 HB).

4718-AChoose it when the part is bent, formed or impact-loaded.

4718-CDChoose it when strength drives the design.

4718-A vs 4718-CD: properties

4718-A4718-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

585 MPa84.8 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
640 MPa92.8 ksi

Elongation at Break

27%
15%

Reduction in Area

58%
45%

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
350 MPa50.8 ksi

Hardness, Brinell

170 HB
229 HB

Hardness, Rockwell B

87 HRB
98 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 380 MPa55.1 ksi · Charpy V-Notch Impact (RT) 60 J44.3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Formability (cold)

55 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 65% · Weldability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4718

4718-A vs 4718-CD — frequently asked

Is 4718-CD stronger than 4718-A?

Yes. 4718-CD has a typical yield strength of 640 MPa (92.8 ksi) against 400 MPa (58 ksi) for 4718-A — about 60% more. Tensile strength is 760 MPa (110 ksi) vs 585 MPa (84.8 ksi).

Which condition does FabDigit quote by default, A or CD?

A is the default 4718 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 4718-A over 4718-CD?

Pick 4718-A when the part is bent, formed or impact-loaded. Pick 4718-CD when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4718-A and 4718-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.