FabDigitFabDigit

Steel 4626 vs 5160

Steel · grade comparison

Steel 4626 and 5160 are both steel grades. 4626 is the stronger of the two: yield strength 350 MPa (50.8 ksi) against 275 MPa (39.9 ksi) for 5160, about 27% more. 4626 is the more ductile: elongation 27% versus 17% for 5160, and 5160 is harder (197 HB vs 156 HB). 4626 runs hotter in service (400°C vs 250°C continuous). On the shop floor, 4626 welds better (fair vs poor) and 4626 sits in a lower cost tier (standard, $$) than 5160 (premium, $$$).

4626Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

4626 vs 5160: properties

46265160

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

540 MPa78.3 ksi
725 MPa105 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
275 MPa39.9 ksi

Elongation at Break

27%
17%

Reduction in Area

60%
31%

Shear Strength

400 MPa58 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
330 MPa47.9 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

156 HB
197 HB

Hardness, Rockwell B

82 HRB
92 HRB

Hardness, Vickers

165 HV
—

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Liquidus Temperature

1,500°C2,732 °F
1,490°C2,714 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
46 W/m·K26.6 BTU/hr·ft·°F

Specific Heat Capacity

475 J/kg·K0.11 BTU/lb·°F
490 J/kg·K0.12 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.9 µm/m·K6.6 µin/in·°F
12.3 µm/m·K6.8 µin/in·°F

Max Service Temperature (continuous)

400°C752 °F
250°C482 °F

Min Service Temperature

-60°C-76 °F
-40°C-40 °F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

12 / 100
10 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
56%

Weldability

50 / 100
25 / 100

Formability (cold)

50 / 100
45 / 100

Brazeability / Solderability

60 / 100
55 / 100

Polishability

65 / 100
70 / 100

Castability

—
40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

32 MJ/kg13,758 BTU/lb
30 MJ/kg12,898 BTU/lb

Embodied Carbon (primary production)

2.3 kg CO₂/kg
2.2 kg CO₂/kg

Typical Recycled Content

25%
35%

Same in both: Embodied Water 60 L/kg7.2 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

69 kN·m/kg
92 kN·m/kg

Modulus of Resilience

299 kJ/m³
184 kJ/m³

Thermal Diffusivity

11.8 mm²/s
12 mm²/s

Thermal Shock Resistance Index

10
13

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale51604626

Manufacturing and finishing

Capability46265160
CNC machining—Yes
Sheet metal—Yes
Default condition—Annealed
Relative cost$$ Standard$$$ Premium
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

4626 vs 5160 — frequently asked

Is 4626 stronger than 5160?

Yes. 4626 has a typical yield strength of 350 MPa (50.8 ksi) against 275 MPa (39.9 ksi) for 5160 — about 27% more. Tensile strength is 540 MPa (78.3 ksi) vs 725 MPa (105 ksi).

Which is cheaper, 4626 or 5160?

4626 is the lower-cost material: it sits in the standard tier ($$) while 5160 is premium ($$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 4626 or 5160?

4626, by a small margin. Both rate good for machinability — 60/100 against 55/100 for 5160; for welding the order is 4626 first (fair, 50/100) then 5160 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4626 and 5160 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.