FabDigitFabDigit

Steel 4621-CD vs 4621-N

Steel · 4621 temper comparison

4621-CD and 4621-N are two conditions of the same steel grade, 4621: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 4621-CD is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 385 MPa (55.8 ksi) for 4621-N, about 45% more; tensile strength follows at 650 MPa (94.3 ksi) vs 595 MPa (86.3 ksi). In exchange, 4621-N is the more ductile: elongation 28% versus 15% for 4621-CD, and 4621-CD is harder (192 HB vs 179 HB).

4621-CDChoose it when strength drives the design.

4621-NChoose it when the part is bent, formed or impact-loaded.

4621-CD vs 4621-N: properties

4621-CD4621-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

650 MPa94.3 ksi
595 MPa86.3 ksi

Yield Strength (0.2% offset)

560 MPa81.2 ksi
385 MPa55.8 ksi

Elongation at Break

15%
28%

Reduction in Area

45%
65%

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
270 MPa39.2 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
125 J92.2 ft·lbf

Hardness, Brinell

192 HB
179 HB

Hardness, Rockwell B

92 HRB
88 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 380 MPa55.1 ksi · Shear Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 100 MPa·√m91 ksi·√in · Hardness, Vickers 164 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
62%

Formability (cold)

35 / 100
60 / 100

Same in both: Weldability 45 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 62 L/kg7.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4621

4621-CD vs 4621-N — frequently asked

Is 4621-CD stronger than 4621-N?

Yes. 4621-CD has a typical yield strength of 560 MPa (81.2 ksi) against 385 MPa (55.8 ksi) for 4621-N — about 45% more. Tensile strength is 650 MPa (94.3 ksi) vs 595 MPa (86.3 ksi).

Which condition does FabDigit quote by default, CD or N?

ANN is the default 4621 condition in the FabDigit quote flow (neither CD nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4621-CD or 4621-N?

4621-CD, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 4621-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4621-CD and 4621-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.