FabDigitFabDigit

Steel 45B-CD vs 45B-IH

Steel · 45B temper comparison

45B-CD and 45B-IH are two conditions of the same steel grade, 45B: CD (cold drawn) versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. 45B-IH is the stronger of the two: yield strength 740 MPa (107 ksi) against 620 MPa (89.9 ksi) for 45B-CD, about 19% more; tensile strength follows at 900 MPa (131 ksi) vs 780 MPa (113 ksi). 45B-IH is the more ductile: elongation 12% versus 10% for 45B-CD, and 45B-IH is harder (590 HB vs 235 HB). 45B-CD runs hotter in service (300°C vs 200°C continuous). On the shop floor, 45B-CD machines more easily (good vs not recommended) and 45B-CD welds better (fair vs not recommended).

45B-CDChoose it when the part sees heat, or when the part is machined in volume.

45B-IHChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

45B-CD vs 45B-IH: properties

45B-CD45B-IH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
740 MPa107 ksi

Elongation at Break

10%
12%

Compressive Strength

620 MPa89.9 ksi
400 MPa58 ksi

Shear Strength

470 MPa68.2 ksi
560 MPa81.2 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
520 MPa75.4 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

235 HB
590 HB

Hardness, Rockwell B

99 HRB
92 HRB

Hardness, Vickers

247 HV
620 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 35%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.6 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.5 % IACS
7.8 % IACS

Electrical Resistivity

2.03×10⁻⁷ Ω·m7.99 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
10%

Weldability

35 / 100
12 / 100

Formability (cold)

25 / 100
5 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale45B

45B-CD vs 45B-IH — frequently asked

Is 45B-IH stronger than 45B-CD?

Yes. 45B-IH has a typical yield strength of 740 MPa (107 ksi) against 620 MPa (89.9 ksi) for 45B-CD — about 19% more. Tensile strength is 900 MPa (131 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, CD or IH?

HR is the default 45B condition in the FabDigit quote flow (neither CD nor IH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 45B-CD or 45B-IH?

45B-CD. Its machinability rates good (62/100) against not recommended (12/100) for 45B-IH; for welding the order is 45B-CD first (fair, 35/100) then 45B-IH (not recommended, 12/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 45B-CD and 45B-IH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.