4419-CD and 4419-N are two conditions of the same steel grade, 4419: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 4419-CD is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 385 MPa (55.8 ksi) for 4419-N, about 30% more; tensile strength follows at 600 MPa (87 ksi) vs 570 MPa (82.7 ksi). In exchange, 4419-N is the more ductile: elongation 22% versus 14% for 4419-CD, and 4419-CD is harder (180 HB vs 170 HB). 4419-N runs hotter in service (400°C vs 300°C continuous).

4419-CDChoose it when strength drives the design.

4419-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4419-CD vs 4419-N: properties

4419-CD4419-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

500 MPa72.5 ksi
385 MPa55.8 ksi

Elongation at Break

14%
22%

Reduction in Area

40%
52%

Shear Strength

395 MPa57.3 ksi
375 MPa54.4 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
275 MPa39.9 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

180 HB
170 HB

Hardness, Rockwell B

89 HRB
86 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
400°C752 °F

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

64 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
60%

Weldability

60 / 100
62 / 100

Formability (cold)

40 / 100
55 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4419

4419-CD vs 4419-N — frequently asked

Is 4419-CD stronger than 4419-N?

Yes. 4419-CD has a typical yield strength of 500 MPa (72.5 ksi) against 385 MPa (55.8 ksi) for 4419-N — about 30% more. Tensile strength is 600 MPa (87 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, CD or N?

A is the default 4419 condition in the FabDigit quote flow (neither CD nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4419-CD or 4419-N?

4419-CD, by a small margin. Both rate good for machinability — 64/100 against 55/100 for 4419-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4419-CD and 4419-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.