FabDigitFabDigit

Steel 42CD4 +C vs 42CD4 +U

Steel · 42CD4 temper comparison

42CD4 +C and 42CD4 +U are two conditions of the same steel grade, 42CD4: +C (cold drawn) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 42CD4 +C is the stronger of the two: yield strength 655 MPa (95 ksi) against 560 MPa (81.2 ksi) for 42CD4 +U, about 17% more. In exchange, 42CD4 +U is the more ductile: elongation 16% versus 14% for 42CD4 +C, and 42CD4 +U is harder (255 HB vs 223 HB). 42CD4 +U runs hotter in service (400°C vs 300°C continuous). On the shop floor, 42CD4 +C machines more easily (good vs fair).

42CD4 +CChoose it when strength drives the design, or when the part is machined in volume.

42CD4 +UChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

42CD4 +C vs 42CD4 +U: properties

42CD4 +C42CD4 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

655 MPa95 ksi
560 MPa81.2 ksi

Elongation at Break

14%
16%

Compressive Strength

655 MPa95 ksi
560 MPa81.2 ksi

Shear Strength

470 MPa68.2 ksi
560 MPa81.2 ksi

Fatigue Strength (Endurance Limit)

345 MPa50 ksi
420 MPa60.9 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
65 MPa·√m59.2 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

223 HB
255 HB

Hardness, Rockwell C

19 HRC
25 HRC

Hardness, Vickers

235 HV
268 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 45%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,416°C2,581 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

43.5 W/m·K25.1 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
400°C752 °F

Same in both: Specific Heat Capacity 473 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

63 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

66%
55%

Weldability

40 / 100
42 / 100

Formability (cold)

35 / 100
40 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale42CD4

42CD4 +C vs 42CD4 +U — frequently asked

Is 42CD4 +C stronger than 42CD4 +U?

Yes. 42CD4 +C has a typical yield strength of 655 MPa (95 ksi) against 560 MPa (81.2 ksi) for 42CD4 +U — about 17% more. Tensile strength is 760 MPa (110 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, +C or +U?

+QT is the default 42CD4 condition in the FabDigit quote flow (neither +C nor +U). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 42CD4 +C or 42CD4 +U?

42CD4 +C. Its machinability rates good (63/100) against fair (52/100) for 42CD4 +U.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 42CD4 +C and 42CD4 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.