FabDigitFabDigit

Steel 35CD4 vs A514

Steel · grade comparison

Steel 35CD4 and A514 are both steel grades. A514 is the stronger of the two: yield strength 760 MPa (110 ksi) against 700 MPa (102 ksi) for 35CD4, about 9% more. A514 is the more ductile: elongation 19% versus 14% for 35CD4, and 35CD4 is harder (285 HB vs 250 HB). 35CD4 runs hotter in service (450°C vs 400°C continuous) and 35CD4 conducts electricity better (8 % IACS vs 7 % IACS). On the shop floor, 35CD4 machines more easily (52 vs 38 out of 100), A514 welds better (good vs fair), and 35CD4 sits in a lower cost tier (budget, $) than A514 (standard, $$).

35CD4Choose it when the part sees heat, or when the part is machined in volume.

A514Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

35CD4 vs A514: properties

35CD4A514

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

210 GPa30.5 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

950 MPa138 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
760 MPa110 ksi

Elongation at Break

14%
19%

Compressive Strength

700 MPa102 ksi
760 MPa110 ksi

Shear Strength

570 MPa82.7 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
380 MPa55.1 ksi

Fracture Toughness (K_IC)

85 MPa·√m77.4 ksi·√in
120 MPa·√m109 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
75 J55.3 ft·lbf

Hardness, Brinell

285 HB
250 HB

Hardness, Rockwell C

29 HRC
24 HRC

Hardness, Vickers

300 HV
262 HV

Hardness, Rockwell B

—
100 HRB

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 50%

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Liquidus Temperature

1,490°C2,714 °F
1,510°C2,750 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Specific Heat Capacity

460 J/kg·K0.11 BTU/lb·°F
470 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.3 µm/m·K6.8 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Max Service Temperature (continuous)

450°C842 °F
400°C752 °F

Min Service Temperature

-40°C-40 °F
-45°C-49 °F

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Latent Heat of Fusion 250 J/g107 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
7 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.61 V
-0.6 V

Corrosion Resistance

12 / 100
16 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
40%

Weldability

45 / 100
55 / 100

Brazeability / Solderability

55 / 100
40 / 100

Polishability

65 / 100
50 / 100

Same in both: Formability (cold) 30 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

33 MJ/kg14,187 BTU/lb
31 MJ/kg13,328 BTU/lb

Embodied Carbon (primary production)

2.3 kg CO₂/kg
2.4 kg CO₂/kg

Embodied Water

60 L/kg7.2 gal/lb
45 L/kg5.4 gal/lb

Same in both: Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

121 kN·m/kg
102 kN·m/kg

Specific Stiffness (E / density)

26.8 MN·m/kg
26.1 MN·m/kg

Modulus of Resilience

1,167 kJ/m³
1,409 kJ/m³

Thermal Diffusivity

11.6 mm²/s
11.4 mm²/s

Thermal Shock Resistance Index

15
14

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA51435CD4

Manufacturing and finishing

Capability35CD4A514
CNC machining—Yes
Sheet metal—Yes
Default condition—Q&T
Relative cost$ Budget$$ Standard
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

35CD4 vs A514 — frequently asked

Is A514 stronger than 35CD4?

Yes. A514 has a typical yield strength of 760 MPa (110 ksi) against 700 MPa (102 ksi) for 35CD4 — about 9% more. Tensile strength is 800 MPa (116 ksi) vs 950 MPa (138 ksi).

Which is cheaper, 35CD4 or A514?

35CD4 is the lower-cost material: it sits in the budget tier ($) while A514 is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 35CD4 or A514?

35CD4, by a small margin. Both rate fair for machinability — 52/100 against 38/100 for A514; for welding the order is A514 first (good, 55/100) then 35CD4 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 35CD4 and A514 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.