FabDigitFabDigit

Steel 30KhGSL-A vs 30KhGSL-QT600

Steel · 30KhGSL temper comparison

30KhGSL-A and 30KhGSL-QT600 are two conditions of the same steel grade, 30KhGSL: A (solution annealed) versus QT600 (Q&T). The chemistry is identical, so every difference below comes from the condition. 30KhGSL-QT600 is the stronger of the two: yield strength 640 MPa (92.8 ksi) against 320 MPa (46.4 ksi) for 30KhGSL-A, about 100% more; tensile strength follows at 820 MPa (119 ksi) vs 560 MPa (81.2 ksi). In exchange, 30KhGSL-A is the more ductile: elongation 18% versus 12% for 30KhGSL-QT600, and 30KhGSL-QT600 is harder (255 HB vs 179 HB). 30KhGSL-QT600 runs hotter in service (450°C vs 400°C continuous). On the shop floor, 30KhGSL-A machines more easily (good vs fair) and 30KhGSL-A welds better (fair vs poor).

30KhGSL-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

30KhGSL-QT600Choose it when strength drives the design, or when the part sees heat.

30KhGSL-A vs 30KhGSL-QT600: properties

30KhGSL-A30KhGSL-QT600

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
820 MPa119 ksi

Yield Strength (0.2% offset)

320 MPa46.4 ksi
640 MPa92.8 ksi

Elongation at Break

18%
12%

Reduction in Area

35%
30%

Compressive Strength

330 MPa47.9 ksi
440 MPa63.8 ksi

Shear Strength

340 MPa49.3 ksi
420 MPa60.9 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
340 MPa49.3 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

179 HB
255 HB

Hardness, Rockwell C

11 HRC
25 HRC

Hardness, Vickers

188 HV
270 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

40 W/m·K23.1 BTU/hr·ft·°F
38 W/m·K22 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
450°C842 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
7.8 % IACS

Electrical Resistivity

2.15×10⁻⁷ Ω·m8.46 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
45%

Weldability

45 / 100
32 / 100

Formability (cold)

22 / 100
15 / 100

Same in both: Castability 58 / 100 · Brazeability / Solderability 45 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale30KhGSL

30KhGSL-A vs 30KhGSL-QT600 — frequently asked

Is 30KhGSL-QT600 stronger than 30KhGSL-A?

Yes. 30KhGSL-QT600 has a typical yield strength of 640 MPa (92.8 ksi) against 320 MPa (46.4 ksi) for 30KhGSL-A — about 100% more. Tensile strength is 820 MPa (119 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, A or QT600?

N+T is the default 30KhGSL condition in the FabDigit quote flow (neither A nor QT600). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 30KhGSL-A or 30KhGSL-QT600?

30KhGSL-A. Its machinability rates good (58/100) against fair (40/100) for 30KhGSL-QT600; for welding the order is 30KhGSL-A first (fair, 45/100) then 30KhGSL-QT600 (poor, 32/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 30KhGSL-A and 30KhGSL-QT600 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.