FabDigitFabDigit

Steel 30CrMnSiA vs A514

Steel · grade comparison

Steel 30CrMnSiA and A514 are both steel grades. 30CrMnSiA is the stronger of the two: yield strength 930 MPa (135 ksi) against 760 MPa (110 ksi) for A514, about 22% more; tensile strength follows at 1,130 MPa (164 ksi) vs 800 MPa (116 ksi). In exchange, A514 is the more ductile: elongation 19% versus 12% for 30CrMnSiA, and 30CrMnSiA is harder (340 HB vs 250 HB). On the shop floor, 30CrMnSiA sits in a lower cost tier (budget, $) than A514 (standard, $$).

30CrMnSiAChoose it when strength drives the design, or when cost is the deciding factor.

A514Choose it when the part is bent, formed or impact-loaded.

30CrMnSiA vs A514: properties

30CrMnSiAA514

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

210 GPa30.5 Msi
205 GPa29.7 Msi

Shear Modulus

81 GPa11.7 Msi
80 GPa11.6 Msi

Bulk Modulus

165 GPa23.9 Msi
160 GPa23.2 Msi

Tensile Strength (Ultimate)

1,130 MPa164 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

930 MPa135 ksi
760 MPa110 ksi

Elongation at Break

12%
19%

Compressive Strength

960 MPa139 ksi
760 MPa110 ksi

Shear Strength

680 MPa98.6 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

520 MPa75.4 ksi
380 MPa55.1 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
120 MPa·√m109 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
75 J55.3 ft·lbf

Hardness, Brinell

340 HB
250 HB

Hardness, Rockwell C

36 HRC
24 HRC

Hardness, Vickers

355 HV
262 HV

Hardness, Rockwell B

—
100 HRB

Same in both: Poisson's Ratio 0.29 · Reduction in Area 50%

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Liquidus Temperature

1,490°C2,714 °F
1,510°C2,750 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38 W/m·K22 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Specific Heat Capacity

480 J/kg·K0.11 BTU/lb·°F
470 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.3 µm/m·K6.3 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Latent Heat of Fusion

260 J/g112 BTU/lb
250 J/g107 BTU/lb

Min Service Temperature

-60°C-76 °F
-45°C-49 °F

Same in both: Max Service Temperature (continuous) 400°C752 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.2 % IACS
7 % IACS

Same in both: Electrical Resistivity 2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

12 / 100
16 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Formability (cold)

35 / 100
30 / 100

Brazeability / Solderability

55 / 100
40 / 100

Polishability

65 / 100
50 / 100

Same in both: Weldability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

34 MJ/kg14,617 BTU/lb
31 MJ/kg13,328 BTU/lb

Embodied Water

60 L/kg7.2 gal/lb
45 L/kg5.4 gal/lb

Typical Recycled Content

25%
30%

Same in both: Embodied Carbon (primary production) 2.4 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

144 kN·m/kg
102 kN·m/kg

Specific Stiffness (E / density)

26.8 MN·m/kg
26.1 MN·m/kg

Modulus of Resilience

2,059 kJ/m³
1,409 kJ/m³

Thermal Diffusivity

10.1 mm²/s
11.4 mm²/s

Thermal Shock Resistance Index

18
14

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA51430CrMnSiA

Manufacturing and finishing

Capability30CrMnSiAA514
CNC machining—Yes
Sheet metal—Yes
Default condition—Q&T
Relative cost$ Budget$$ Standard
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

30CrMnSiA vs A514 — frequently asked

Is 30CrMnSiA stronger than A514?

Yes. 30CrMnSiA has a typical yield strength of 930 MPa (135 ksi) against 760 MPa (110 ksi) for A514 — about 22% more. Tensile strength is 1,130 MPa (164 ksi) vs 800 MPa (116 ksi).

Which is cheaper, 30CrMnSiA or A514?

30CrMnSiA is the lower-cost material: it sits in the budget tier ($) while A514 is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

When should I choose 30CrMnSiA over A514?

Pick 30CrMnSiA when strength drives the design, or when cost is the deciding factor. Pick A514 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 30CrMnSiA and A514 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.