FabDigitFabDigit

Steel 30CrMnSiA-CD vs 30CrMnSiA-HR

Steel · 30CrMnSiA temper comparison

30CrMnSiA-CD and 30CrMnSiA-HR are two conditions of the same steel grade, 30CrMnSiA: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 30CrMnSiA-CD is the stronger of the two: yield strength 720 MPa (104 ksi) against 480 MPa (69.6 ksi) for 30CrMnSiA-HR, about 50% more; tensile strength follows at 880 MPa (128 ksi) vs 780 MPa (113 ksi). In exchange, 30CrMnSiA-HR is the more ductile: elongation 16% versus 10% for 30CrMnSiA-CD, and 30CrMnSiA-CD is harder (265 HB vs 245 HB). 30CrMnSiA-HR runs hotter in service (400°C vs 350°C continuous). On the shop floor, 30CrMnSiA-HR welds better (good vs fair).

30CrMnSiA-CDChoose it when strength drives the design.

30CrMnSiA-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

30CrMnSiA-CD vs 30CrMnSiA-HR: properties

30CrMnSiA-CD30CrMnSiA-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

880 MPa128 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

720 MPa104 ksi
480 MPa69.6 ksi

Elongation at Break

10%
16%

Reduction in Area

40%
45%

Compressive Strength

745 MPa108 ksi
500 MPa72.5 ksi

Shear Strength

530 MPa76.9 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

395 MPa57.3 ksi
350 MPa50.8 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

265 HB
245 HB

Hardness, Rockwell C

27 HRC
23 HRC

Hardness, Vickers

278 HV
255 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

41 W/m·K23.7 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.3 µm/m·K6.3 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.3 % IACS
7.5 % IACS

Electrical Resistivity

2.36×10⁻⁷ Ω·m9.29 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
55%

Weldability

50 / 100
60 / 100

Formability (cold)

25 / 100
40 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale30CrMnSiA

30CrMnSiA-CD vs 30CrMnSiA-HR — frequently asked

Is 30CrMnSiA-CD stronger than 30CrMnSiA-HR?

Yes. 30CrMnSiA-CD has a typical yield strength of 720 MPa (104 ksi) against 480 MPa (69.6 ksi) for 30CrMnSiA-HR — about 50% more. Tensile strength is 880 MPa (128 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, CD or HR?

QT1080 is the default 30CrMnSiA condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 30CrMnSiA-CD or 30CrMnSiA-HR?

30CrMnSiA-HR. Its weldability rates good (60/100) against fair (50/100) for 30CrMnSiA-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 30CrMnSiA-CD and 30CrMnSiA-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.