FabDigitFabDigit

Steel 25L N+T vs 25L-QT

Steel · 25L temper comparison

25L N+T and 25L-QT are two conditions of the same steel grade, 25L: N+T (normalized and tempered) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 25L-QT is the stronger of the two: yield strength 360 MPa (52.2 ksi) against 250 MPa (36.3 ksi) for 25L N+T, about 44% more; tensile strength follows at 580 MPa (84.1 ksi) vs 470 MPa (68.2 ksi). In exchange, 25L N+T is the more ductile: elongation 21% versus 17% for 25L-QT, and 25L-QT is harder (185 HB vs 145 HB).

25L N+TChoose it when the part is bent, formed or impact-loaded.

25L-QTChoose it when strength drives the design.

25L N+T vs 25L-QT: properties

25L N+T25L-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
360 MPa52.2 ksi

Elongation at Break

21%
17%

Reduction in Area

35%
40%

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

145 HB
185 HB

Hardness, Rockwell B

78 HRB
90 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 250 MPa36.3 ksi · Shear Strength 310 MPa45 ksi · Fracture Toughness (K_IC) 75 MPa·√m68.3 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.83 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
60%

Same in both: Weldability 85 / 100 · Formability (cold) 25 / 100 · Castability 72 / 100 · Brazeability / Solderability 65 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale25L

25L N+T vs 25L-QT — frequently asked

Is 25L-QT stronger than 25L N+T?

Yes. 25L-QT has a typical yield strength of 360 MPa (52.2 ksi) against 250 MPa (36.3 ksi) for 25L N+T — about 44% more. Tensile strength is 580 MPa (84.1 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, N+T or QT?

N+T is the default 25L condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 25L N+T or 25L-QT?

25L N+T. Its machinability rates good (58/100) against fair (52/100) for 25L-QT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 25L N+T and 25L-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.