FabDigitFabDigit

Steel 25L-ANN vs 25L-N

Steel · 25L temper comparison

25L-ANN and 25L-N are two conditions of the same steel grade, 25L: ANN (annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 25L-N is the stronger of the two: yield strength 255 MPa (37 ksi) against 225 MPa (32.6 ksi) for 25L-ANN, about 13% more; tensile strength follows at 470 MPa (68.2 ksi) vs 440 MPa (63.8 ksi). In exchange, 25L-ANN is the more ductile: elongation 23% versus 20% for 25L-N, and 25L-N is harder (150 HB vs 130 HB).

25L-ANNChoose it when the part is bent, formed or impact-loaded.

25L-NChoose it when strength drives the design.

25L-ANN vs 25L-N: properties

25L-ANN25L-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

440 MPa63.8 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

225 MPa32.6 ksi
255 MPa37 ksi

Elongation at Break

23%
20%

Reduction in Area

38%
34%

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
195 MPa28.3 ksi

Hardness, Brinell

130 HB
150 HB

Hardness, Rockwell B

72 HRB
80 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 250 MPa36.3 ksi · Shear Strength 310 MPa45 ksi · Fracture Toughness (K_IC) 75 MPa·√m68.3 ksi·√in · Charpy V-Notch Impact (RT) 24 J17.7 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.83 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
68%

Same in both: Weldability 85 / 100 · Formability (cold) 25 / 100 · Castability 72 / 100 · Brazeability / Solderability 65 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale25L

25L-ANN vs 25L-N — frequently asked

Is 25L-N stronger than 25L-ANN?

Yes. 25L-N has a typical yield strength of 255 MPa (37 ksi) against 225 MPa (32.6 ksi) for 25L-ANN — about 13% more. Tensile strength is 470 MPa (68.2 ksi) vs 440 MPa (63.8 ksi).

Which condition does FabDigit quote by default, ANN or N?

N+T is the default 25L condition in the FabDigit quote flow (neither ANN nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 25L-ANN over 25L-N?

Pick 25L-ANN when the part is bent, formed or impact-loaded. Pick 25L-N when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 25L-ANN and 25L-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.