FabDigitFabDigit

Steel 25CrMo4 +C vs 25CrMo4 Q&T

Steel · 25CrMo4 temper comparison

25CrMo4 +C and 25CrMo4 Q&T are two conditions of the same steel grade, 25CrMo4: +C (cold drawn) versus Q&T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 25CrMo4 Q&T is the stronger of the two: tensile strength 870 MPa (126 ksi) against 780 MPa (113 ksi) for 25CrMo4 +C, about 12% more. 25CrMo4 Q&T is the more ductile: elongation 16% versus 10% for 25CrMo4 +C, and 25CrMo4 Q&T is harder (270 HB vs 235 HB). On the shop floor, 25CrMo4 +C machines more easily (65 vs 55 out of 100).

25CrMo4 +CChoose it when the part is machined in volume.

25CrMo4 Q&TChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

25CrMo4 +C vs 25CrMo4 Q&T: properties

25CrMo4 +C25CrMo4 Q&T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
870 MPa126 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
650 MPa94.3 ksi

Elongation at Break

10%
16%

Reduction in Area

40%
50%

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
450 MPa65.3 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

235 HB
270 HB

Hardness, Vickers

245 HV
285 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 660 MPa95.7 ksi · Shear Strength 520 MPa75.4 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Hardness, Rockwell C 28 HRC

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 500°C932 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
60%

Formability (cold)

35 / 100
45 / 100

Same in both: Weldability 65 / 100 · Brazeability / Solderability 60 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale25CrMo4

25CrMo4 +C vs 25CrMo4 Q&T — frequently asked

Is 25CrMo4 Q&T stronger than 25CrMo4 +C?

Yes. 25CrMo4 Q&T has a typical tensile strength of 870 MPa (126 ksi) against 780 MPa (113 ksi) for 25CrMo4 +C — about 12% more.

Which condition does FabDigit quote by default, +C or Q&T?

Q&T is the default 25CrMo4 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 25CrMo4 +C or 25CrMo4 Q&T?

25CrMo4 +C, by a small margin. Both rate good for machinability — 65/100 against 55/100 for 25CrMo4 Q&T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 25CrMo4 +C and 25CrMo4 Q&T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.