FabDigitFabDigit

Steel 22MnB4 +AC+C vs 22MnB4 +U

Steel · 22MnB4 temper comparison

22MnB4 +AC+C and 22MnB4 +U are two conditions of the same steel grade, 22MnB4: +AC+C (spheroidize annealed and cold drawn) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 22MnB4 +AC+C is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 390 MPa (56.6 ksi) for 22MnB4 +U, about 15% more. In exchange, 22MnB4 +U is the more ductile: elongation 20% versus 14% for 22MnB4 +AC+C, and 22MnB4 +U is harder (180 HB vs 165 HB). 22MnB4 +U runs hotter in service (450°C vs 400°C continuous).

22MnB4 +AC+CChoose it when strength drives the design.

22MnB4 +UChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

22MnB4 +AC+C vs 22MnB4 +U: properties

22MnB4 +AC+C22MnB4 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
600 MPa87 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
390 MPa56.6 ksi

Elongation at Break

14%
20%

Reduction in Area

62%
58%

Shear Strength

340 MPa49.3 ksi
365 MPa52.9 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
270 MPa39.2 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

165 HB
180 HB

Hardness, Rockwell B

85 HRB
89 HRB

Hardness, Vickers

175 HV
190 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 450 MPa65.3 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
450°C842 °F

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.6 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

60 / 100
62 / 100

Formability (cold)

82 / 100
60 / 100

Same in both: Machinability 55 / 100 · Machinability Rating (AISI 1212 = 100 %) 60% · Brazeability / Solderability 55 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale22MnB4

22MnB4 +AC+C vs 22MnB4 +U — frequently asked

Is 22MnB4 +AC+C stronger than 22MnB4 +U?

Yes. 22MnB4 +AC+C has a typical yield strength of 450 MPa (65.3 ksi) against 390 MPa (56.6 ksi) for 22MnB4 +U — about 15% more. Tensile strength is 560 MPa (81.2 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, +AC+C or +U?

+AC+C is the default 22MnB4 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 22MnB4 +AC+C over 22MnB4 +U?

Pick 22MnB4 +AC+C when strength drives the design. Pick 22MnB4 +U when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 22MnB4 +AC+C and 22MnB4 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.