20MnB4 +AC+C and 20MnB4 +U are two conditions of the same steel grade, 20MnB4: +AC+C (spheroidize annealed then cold drawn) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 20MnB4 +AC+C is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 390 MPa (56.6 ksi) for 20MnB4 +U, about 15% more. In exchange, 20MnB4 +U is the more ductile: elongation 20% versus 13% for 20MnB4 +AC+C, and 20MnB4 +U is harder (170 HB vs 160 HB).

20MnB4 +AC+CChoose it when strength drives the design.

20MnB4 +UChoose it when the part is bent, formed or impact-loaded.

20MnB4 +AC+C vs 20MnB4 +U: properties

20MnB4 +AC+C20MnB4 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
390 MPa56.6 ksi

Elongation at Break

13%
20%

Reduction in Area

62%
58%

Shear Strength

340 MPa49.3 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

160 HB
170 HB

Hardness, Rockwell B

84 HRB
87 HRB

Hardness, Vickers

168 HV
178 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 455 MPa66 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.6 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

62%
60%

Formability (cold)

85 / 100
70 / 100

Same in both: Machinability 55 / 100 · Weldability 55 / 100 · Brazeability / Solderability 60 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20MnB4

20MnB4 +AC+C vs 20MnB4 +U — frequently asked

Is 20MnB4 +AC+C stronger than 20MnB4 +U?

Yes. 20MnB4 +AC+C has a typical yield strength of 450 MPa (65.3 ksi) against 390 MPa (56.6 ksi) for 20MnB4 +U — about 15% more. Tensile strength is 550 MPa (79.8 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, +AC+C or +U?

+AC+C is the default 20MnB4 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 20MnB4 +AC+C over 20MnB4 +U?

Pick 20MnB4 +AC+C when strength drives the design. Pick 20MnB4 +U when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20MnB4 +AC+C and 20MnB4 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.