FabDigitFabDigit

Steel 20Mn5 vs P355GH

Steel · grade comparison

Steel 20Mn5 and P355GH are both steel grades. P355GH is the stronger of the two: yield strength 385 MPa (55.8 ksi) against 320 MPa (46.4 ksi) for 20Mn5, about 20% more. P355GH is harder — 165 HB against 155 HB for 20Mn5 — which matters for wear surfaces and threads. On the shop floor, 20Mn5 sits in a lower cost tier (budget, $) than P355GH (standard, $$).

20Mn5Choose it when cost is the deciding factor.

P355GHChoose it when strength drives the design, or when surface hardness matters.

20Mn5 vs P355GH: properties

20Mn5P355GH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

530 MPa76.9 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

320 MPa46.4 ksi
385 MPa55.8 ksi

Elongation at Break

25%
24%

Reduction in Area

55%
50%

Compressive Strength

320 MPa46.4 ksi
385 MPa55.8 ksi

Shear Strength

330 MPa47.9 ksi
340 MPa49.3 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
100 MPa·√m91 ksi·√in

Hardness, Brinell

155 HB
165 HB

Hardness, Rockwell B

82 HRB
85 HRB

Hardness, Vickers

163 HV
173 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fatigue Strength (Endurance Limit) 245 MPa35.5 ksi · Charpy V-Notch Impact (RT) 70 J51.6 ft·lbf

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,425°C2,597 °F
1,460°C2,660 °F

Liquidus Temperature

1,500°C2,732 °F
1,510°C2,750 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Specific Heat Capacity

470 J/kg·K0.11 BTU/lb·°F
461 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.2 µm/m·K6.8 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Latent Heat of Fusion

270 J/g116 BTU/lb
260 J/g112 BTU/lb

Max Service Temperature (continuous)

400°C752 °F
380°C716 °F

Min Service Temperature

-46°C-51 °F
-10°C14 °F

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F

Electrical

Conductivity and insulation.

Electrical Conductivity

9 % IACS
8.2 % IACS

Electrical Resistivity

1.9×10⁻⁷ Ω·m7.48 µΩ·in
2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

11 / 100
12 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
62%

Weldability

78 / 100
85 / 100

Formability (cold)

60 / 100
64 / 100

Brazeability / Solderability

65 / 100
50 / 100

Same in both: Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

45 L/kg5.4 gal/lb
40 L/kg4.8 gal/lb

Typical Recycled Content

30%
25%

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

68 kN·m/kg
70 kN·m/kg

Modulus of Resilience

244 kJ/m³
353 kJ/m³

Thermal Diffusivity

13 mm²/s
13.3 mm²/s

Same in both: Specific Stiffness (E / density) 26.8 MN·m/kg · Thermal Shock Resistance Index 10

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP355GH20Mn5

Manufacturing and finishing

Capability20Mn5P355GH
CNC machining—Yes
Sheet metal—Yes
Default condition—HR
Relative cost$ Budget$$ Standard
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

20Mn5 vs P355GH — frequently asked

Is P355GH stronger than 20Mn5?

Yes. P355GH has a typical yield strength of 385 MPa (55.8 ksi) against 320 MPa (46.4 ksi) for 20Mn5 — about 20% more. Tensile strength is 550 MPa (79.8 ksi) vs 530 MPa (76.9 ksi).

Which is cheaper, 20Mn5 or P355GH?

20Mn5 is the lower-cost material: it sits in the budget tier ($) while P355GH is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which welds better, 20Mn5 or P355GH?

P355GH. Its weldability rates excellent (85/100) against very good (78/100) for 20Mn5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20Mn5 and P355GH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.