FabDigitFabDigit

Steel 20Mn5 +A vs 20Mn5 +N

Steel · 20Mn5 temper comparison

20Mn5 +A and 20Mn5 +N are two conditions of the same steel grade, 20Mn5: +A (annealed) versus +N (normalized). The chemistry is identical, so every difference below comes from the condition. 20Mn5 +N is the stronger of the two: yield strength 310 MPa (45 ksi) against 260 MPa (37.7 ksi) for 20Mn5 +A, about 19% more; tensile strength follows at 520 MPa (75.4 ksi) vs 460 MPa (66.7 ksi). In exchange, 20Mn5 +A is the more ductile: elongation 30% versus 25% for 20Mn5 +N, and 20Mn5 +N is harder (152 HB vs 135 HB).

20Mn5 +AChoose it when the part is bent, formed or impact-loaded.

20Mn5 +NChoose it when strength drives the design.

20Mn5 +A vs 20Mn5 +N: properties

20Mn5 +A20Mn5 +N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

460 MPa66.7 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
310 MPa45 ksi

Elongation at Break

30%
25%

Reduction in Area

60%
55%

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
240 MPa34.8 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

135 HB
152 HB

Hardness, Rockwell B

75 HRB
81 HRB

Hardness, Vickers

142 HV
160 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 320 MPa46.4 ksi · Shear Strength 330 MPa47.9 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -46°C-51 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
65%

Weldability

80 / 100
78 / 100

Formability (cold)

70 / 100
60 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20Mn5

20Mn5 +A vs 20Mn5 +N — frequently asked

Is 20Mn5 +N stronger than 20Mn5 +A?

Yes. 20Mn5 +N has a typical yield strength of 310 MPa (45 ksi) against 260 MPa (37.7 ksi) for 20Mn5 +A — about 19% more. Tensile strength is 520 MPa (75.4 ksi) vs 460 MPa (66.7 ksi).

Which condition does FabDigit quote by default, +A or +N?

+NT is the default 20Mn5 condition in the FabDigit quote flow (neither +A nor +N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 20Mn5 +A over 20Mn5 +N?

Pick 20Mn5 +A when the part is bent, formed or impact-loaded. Pick 20Mn5 +N when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20Mn5 +A and 20Mn5 +N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.