FabDigitFabDigit

Steel 20#-CD vs 20#-QT

Steel · 20# temper comparison

20#-CD and 20#-QT are two conditions of the same steel grade, 20#: CD (cold drawn) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 20#-QT is the stronger of the two: yield strength 430 MPa (62.4 ksi) against 395 MPa (57.3 ksi) for 20#-CD, about 9% more; tensile strength follows at 600 MPa (87 ksi) vs 510 MPa (74 ksi). 20#-QT is the more ductile: elongation 20% versus 13% for 20#-CD, and 20#-QT is harder (190 HB vs 160 HB). On the shop floor, 20#-CD machines more easily (good vs fair).

20#-CDChoose it when the part is machined in volume.

20#-QTChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

20#-CD vs 20#-QT: properties

20#-CD20#-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

510 MPa74 ksi
600 MPa87 ksi

Yield Strength (0.2% offset)

395 MPa57.3 ksi
430 MPa62.4 ksi

Elongation at Break

13%
20%

Reduction in Area

45%
50%

Shear Strength

330 MPa47.9 ksi
375 MPa54.4 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
280 MPa40.6 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

160 HB
190 HB

Hardness, Rockwell B

83 HRB
91 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

425°C797 °F
400°C752 °F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 272 J/g117 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.5 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
58%

Weldability

92 / 100
88 / 100

Formability (cold)

60 / 100
55 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 80 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20#

20#-CD vs 20#-QT — frequently asked

Is 20#-QT stronger than 20#-CD?

Yes. 20#-QT has a typical yield strength of 430 MPa (62.4 ksi) against 395 MPa (57.3 ksi) for 20#-CD — about 9% more. Tensile strength is 600 MPa (87 ksi) vs 510 MPa (74 ksi).

Which condition does FabDigit quote by default, CD or QT?

CD is the default 20# condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20#-CD or 20#-QT?

20#-CD. Its machinability rates good (65/100) against fair (52/100) for 20#-QT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20#-CD and 20#-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.