FabDigitFabDigit

Steel 20#-CD vs 20#-HR

Steel · 20# temper comparison

20#-CD and 20#-HR are two conditions of the same steel grade, 20#: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 20#-CD is the stronger of the two: yield strength 395 MPa (57.3 ksi) against 265 MPa (38.4 ksi) for 20#-HR, about 49% more; tensile strength follows at 510 MPa (74 ksi) vs 440 MPa (63.8 ksi). In exchange, 20#-HR is the more ductile: elongation 28% versus 13% for 20#-CD, and 20#-CD is harder (160 HB vs 145 HB).

20#-CDChoose it when strength drives the design.

20#-HRChoose it when the part is bent, formed or impact-loaded.

20#-CD vs 20#-HR: properties

20#-CD20#-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

510 MPa74 ksi
440 MPa63.8 ksi

Yield Strength (0.2% offset)

395 MPa57.3 ksi
265 MPa38.4 ksi

Elongation at Break

13%
28%

Reduction in Area

45%
58%

Shear Strength

330 MPa47.9 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
215 MPa31.2 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

160 HB
145 HB

Hardness, Rockwell B

83 HRB
78 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 100 MPa·√m91 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 272 J/g117 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
65%

Weldability

92 / 100
95 / 100

Formability (cold)

60 / 100
80 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 80 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale20#

20#-CD vs 20#-HR — frequently asked

Is 20#-CD stronger than 20#-HR?

Yes. 20#-CD has a typical yield strength of 395 MPa (57.3 ksi) against 265 MPa (38.4 ksi) for 20#-HR — about 49% more. Tensile strength is 510 MPa (74 ksi) vs 440 MPa (63.8 ksi).

Which condition does FabDigit quote by default, CD or HR?

CD is the default 20# condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 20#-CD or 20#-HR?

20#-CD, by a small margin. Both rate good for machinability — 65/100 against 58/100 for 20#-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 20#-CD and 20#-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.