FabDigitFabDigit

Steel 17CrNiMo6 Annealed vs 17CrNiMo6 +S

Steel · 17CrNiMo6 temper comparison

17CrNiMo6 Annealed and 17CrNiMo6 +S are two conditions of the same steel grade, 17CrNiMo6: Annealed versus +S (treated for shearability). The chemistry is identical, so every difference below comes from the condition. 17CrNiMo6 +S is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 430 MPa (62.4 ksi) for 17CrNiMo6 Annealed, about 12% more; tensile strength follows at 780 MPa (113 ksi) vs 700 MPa (102 ksi). In exchange, 17CrNiMo6 Annealed is the more ductile: elongation 20% versus 16% for 17CrNiMo6 +S, and 17CrNiMo6 +S is harder (225 HB vs 200 HB). 17CrNiMo6 Annealed runs hotter in service (300°C vs 200°C continuous).

17CrNiMo6 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

17CrNiMo6 +SChoose it when strength drives the design.

17CrNiMo6 Annealed vs 17CrNiMo6 +S: properties

17CrNiMo6 Annealed17CrNiMo6 +S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

430 MPa62.4 ksi
480 MPa69.6 ksi

Elongation at Break

20%
16%

Reduction in Area

55%
50%

Shear Strength

430 MPa62.4 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
350 MPa50.8 ksi

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

200 HB
225 HB

Hardness, Rockwell B

93 HRB
98 HRB

Hardness, Vickers

210 HV
236 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Thermal Conductivity 38 W/m·K22 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
52%

Formability (cold)

40 / 100
48 / 100

Same in both: Weldability 30 / 100 · Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale17CrNiMo6

17CrNiMo6 Annealed vs 17CrNiMo6 +S — frequently asked

Is 17CrNiMo6 +S stronger than 17CrNiMo6 Annealed?

Yes. 17CrNiMo6 +S has a typical yield strength of 480 MPa (69.6 ksi) against 430 MPa (62.4 ksi) for 17CrNiMo6 Annealed — about 12% more. Tensile strength is 780 MPa (113 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, Annealed or +S?

Annealed is the default 17CrNiMo6 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 17CrNiMo6 Annealed over 17CrNiMo6 +S?

Pick 17CrNiMo6 Annealed when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 17CrNiMo6 +S when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 17CrNiMo6 Annealed and 17CrNiMo6 +S side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.