FabDigitFabDigit

Steel 16NC6 +A vs 16NC6-CH

Steel · 16NC6 temper comparison

16NC6 +A and 16NC6-CH are two conditions of the same steel grade, 16NC6: +A (annealed) versus CH (carburized and hardened). The chemistry is identical, so every difference below comes from the condition. 16NC6-CH is the stronger of the two: yield strength 680 MPa (98.6 ksi) against 350 MPa (50.8 ksi) for 16NC6 +A, about 94% more; tensile strength follows at 950 MPa (138 ksi) vs 560 MPa (81.2 ksi). In exchange, 16NC6 +A is the more ductile: elongation 22% versus 10% for 16NC6-CH, and 16NC6-CH is harder (280 HB vs 170 HB). 16NC6 +A runs hotter in service (300°C vs 180°C continuous). On the shop floor, 16NC6 +A machines more easily (good vs poor) and 16NC6 +A welds better (good vs not recommended).

16NC6 +AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

16NC6-CHChoose it when strength drives the design.

16NC6 +A vs 16NC6-CH: properties

16NC6 +A16NC6-CH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
950 MPa138 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
680 MPa98.6 ksi

Elongation at Break

22%
10%

Reduction in Area

55%
45%

Shear Strength

380 MPa55.1 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

270 MPa39.2 ksi
520 MPa75.4 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

170 HB
280 HB

Hardness, Vickers

180 HV
720 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 87 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
180°C356 °F

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
15%

Weldability

60 / 100
10 / 100

Formability (cold)

65 / 100
5 / 100

Polishability

60 / 100
75 / 100

Same in both: Brazeability / Solderability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale16NC6

16NC6 +A vs 16NC6-CH — frequently asked

Is 16NC6-CH stronger than 16NC6 +A?

Yes. 16NC6-CH has a typical yield strength of 680 MPa (98.6 ksi) against 350 MPa (50.8 ksi) for 16NC6 +A — about 94% more. Tensile strength is 950 MPa (138 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, +A or CH?

+A is the default 16NC6 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 16NC6 +A or 16NC6-CH?

16NC6 +A. Its machinability rates good (60/100) against poor (15/100) for 16NC6-CH; for welding the order is 16NC6 +A first (good, 60/100) then 16NC6-CH (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 16NC6 +A and 16NC6-CH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.