FabDigitFabDigit

Steel 16NC6 +A vs 16NC6 +C

Steel · 16NC6 temper comparison

16NC6 +A and 16NC6 +C are two conditions of the same steel grade, 16NC6: +A (annealed) versus +C (cold drawn). The chemistry is identical, so every difference below comes from the condition. 16NC6 +C is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 350 MPa (50.8 ksi) for 16NC6 +A, about 57% more; tensile strength follows at 700 MPa (102 ksi) vs 560 MPa (81.2 ksi). In exchange, 16NC6 +A is the more ductile: elongation 22% versus 11% for 16NC6 +C, and 16NC6 +C is harder (215 HB vs 170 HB).

16NC6 +AChoose it when the part is bent, formed or impact-loaded.

16NC6 +CChoose it when strength drives the design.

16NC6 +A vs 16NC6 +C: properties

16NC6 +A16NC6 +C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
550 MPa79.8 ksi

Elongation at Break

22%
11%

Reduction in Area

55%
45%

Fatigue Strength (Endurance Limit)

270 MPa39.2 ksi
320 MPa46.4 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

170 HB
215 HB

Hardness, Rockwell B

87 HRB
96 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Hardness, Vickers 180 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
68%

Formability (cold)

65 / 100
40 / 100

Same in both: Weldability 60 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale16NC6

16NC6 +A vs 16NC6 +C — frequently asked

Is 16NC6 +C stronger than 16NC6 +A?

Yes. 16NC6 +C has a typical yield strength of 550 MPa (79.8 ksi) against 350 MPa (50.8 ksi) for 16NC6 +A — about 57% more. Tensile strength is 700 MPa (102 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, +A or +C?

+A is the default 16NC6 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 16NC6 +A or 16NC6 +C?

16NC6 +C, by a small margin. Both rate good for machinability — 68/100 against 60/100 for 16NC6 +A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 16NC6 +A and 16NC6 +C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.