Steel 15MnCrMoNiV5-3-HR vs 15MnCrMoNiV5-3 +SR

Steel · 15MnCrMoNiV5-3 temper comparison

15MnCrMoNiV5-3-HR and 15MnCrMoNiV5-3 +SR are two conditions of the same steel grade, 15MnCrMoNiV5-3: HR (hot rolled) versus +SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. 15MnCrMoNiV5-3 +SR is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 450 MPa (65.3 ksi) for 15MnCrMoNiV5-3-HR, about 27% more; tensile strength follows at 780 MPa (113 ksi) vs 700 MPa (102 ksi). 15MnCrMoNiV5-3 +SR is harder — 235 HB against 215 HB for 15MnCrMoNiV5-3-HR — which matters for wear surfaces and threads. 15MnCrMoNiV5-3 +SR runs hotter in service (520°C vs 450°C continuous).

15MnCrMoNiV5-3 +SRChoose it when strength drives the design, or when surface hardness matters.

15MnCrMoNiV5-3-HR vs 15MnCrMoNiV5-3 +SR: properties

15MnCrMoNiV5-3-HR15MnCrMoNiV5-3 +SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
570 MPa82.7 ksi

Elongation at Break

18%
17%

Reduction in Area

45%
50%

Compressive Strength

460 MPa66.7 ksi
580 MPa84.1 ksi

Shear Strength

420 MPa60.9 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

315 MPa45.7 ksi
355 MPa51.5 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

215 HB
235 HB

Hardness, Rockwell C

18 HRC
21 HRC

Hardness, Vickers

226 HV
246 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

40 W/m·K23.1 BTU/hr·ft·°F
38 W/m·K22 BTU/hr·ft·°F

Max Service Temperature (continuous)

450°C842 °F
520°C968 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
7.5 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
52%

Formability (cold)

45 / 100
37 / 100

Same in both: Weldability 55 / 100 · Castability 30 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale15MnCrMoNiV5-3

15MnCrMoNiV5-3-HR vs 15MnCrMoNiV5-3 +SR — frequently asked

Is 15MnCrMoNiV5-3 +SR stronger than 15MnCrMoNiV5-3-HR?

Yes. 15MnCrMoNiV5-3 +SR has a typical yield strength of 570 MPa (82.7 ksi) against 450 MPa (65.3 ksi) for 15MnCrMoNiV5-3-HR — about 27% more. Tensile strength is 780 MPa (113 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, HR or +SR?

+QT is the default 15MnCrMoNiV5-3 condition in the FabDigit quote flow (neither HR nor +SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 15MnCrMoNiV5-3-HR over 15MnCrMoNiV5-3 +SR?

Pick 15MnCrMoNiV5-3 +SR when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 15MnCrMoNiV5-3-HR and 15MnCrMoNiV5-3 +SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.