FabDigitFabDigit

Steel 15B2 +AC vs 15B2 +U

Steel · 15B2 temper comparison

15B2 +AC and 15B2 +U are two conditions of the same steel grade, 15B2: +AC (spheroidize annealed) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. 15B2 +U is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for 15B2 +AC, about 20% more; tensile strength follows at 460 MPa (66.7 ksi) vs 400 MPa (58 ksi). In exchange, 15B2 +AC is the more ductile: elongation 32% versus 24% for 15B2 +U, and 15B2 +U is harder (135 HB vs 115 HB).

15B2 +ACChoose it when the part is bent, formed or impact-loaded.

15B2 +UChoose it when strength drives the design.

15B2 +AC vs 15B2 +U: properties

15B2 +AC15B2 +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
460 MPa66.7 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
300 MPa43.5 ksi

Elongation at Break

32%
24%

Reduction in Area

72%
62%

Shear Strength

260 MPa37.7 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
210 MPa30.5 ksi

Charpy V-Notch Impact (RT)

85 J62.7 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

115 HB
135 HB

Hardness, Rockwell B

65 HRB
75 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 420 MPa60.9 ksi · Fracture Toughness (K_IC) 120 MPa·√m109 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,465°C2,669 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
55%

Formability (cold)

95 / 100
78 / 100

Same in both: Weldability 82 / 100 · Brazeability / Solderability 70 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale15B2

15B2 +AC vs 15B2 +U — frequently asked

Is 15B2 +U stronger than 15B2 +AC?

Yes. 15B2 +U has a typical yield strength of 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for 15B2 +AC — about 20% more. Tensile strength is 460 MPa (66.7 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, +AC or +U?

+AC+C is the default 15B2 condition in the FabDigit quote flow (neither +AC nor +U). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 15B2 +AC or 15B2 +U?

15B2 +U, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 15B2 +AC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 15B2 +AC and 15B2 +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.