FabDigitFabDigit

Steel 1345-A vs 1345-N

Steel · 1345 temper comparison

1345-A and 1345-N are two conditions of the same steel grade, 1345: A (solution annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1345-N is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 440 MPa (63.8 ksi) for 1345-A, about 32% more; tensile strength follows at 890 MPa (129 ksi) vs 725 MPa (105 ksi). In exchange, 1345-A is the more ductile: elongation 20% versus 18% for 1345-N, and 1345-N is harder (262 HB vs 205 HB).

1345-AChoose it when the part is bent, formed or impact-loaded.

1345-NChoose it when strength drives the design.

1345-A vs 1345-N: properties

1345-A1345-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
890 MPa129 ksi

Yield Strength (0.2% offset)

440 MPa63.8 ksi
580 MPa84.1 ksi

Elongation at Break

20%
18%

Reduction in Area

45%
50%

Shear Strength

435 MPa63.1 ksi
535 MPa77.6 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
400 MPa58 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

205 HB
262 HB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 440 MPa63.8 ksi · Fracture Toughness (K_IC) 60 MPa·√m54.6 ksi·√in · Hardness, Rockwell B 94 HRB · Hardness, Vickers 215 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Thermal Conductivity 43 W/m·K24.8 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
45%

Formability (cold)

40 / 100
25 / 100

Same in both: Weldability 30 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1345

1345-A vs 1345-N — frequently asked

Is 1345-N stronger than 1345-A?

Yes. 1345-N has a typical yield strength of 580 MPa (84.1 ksi) against 440 MPa (63.8 ksi) for 1345-A — about 32% more. Tensile strength is 890 MPa (129 ksi) vs 725 MPa (105 ksi).

Which condition does FabDigit quote by default, A or N?

A is the default 1345 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1345-A or 1345-N?

1345-A, by a small margin. Both rate fair for machinability — 45/100 against 38/100 for 1345-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1345-A and 1345-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.