FabDigitFabDigit

Steel 1145-CD vs 1145-HR

Steel · 1145 temper comparison

1145-CD and 1145-HR are two conditions of the same steel grade, 1145: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1145-CD is the stronger of the two: yield strength 565 MPa (81.9 ksi) against 325 MPa (47.1 ksi) for 1145-HR, about 74% more; tensile strength follows at 655 MPa (95 ksi) vs 585 MPa (84.8 ksi). In exchange, 1145-HR is the more ductile: elongation 18% versus 12% for 1145-CD, and 1145-CD is harder (187 HB vs 170 HB).

1145-CDChoose it when strength drives the design.

1145-HRChoose it when the part is bent, formed or impact-loaded.

1145-CD vs 1145-HR: properties

1145-CD1145-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

655 MPa95 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

565 MPa81.9 ksi
325 MPa47.1 ksi

Elongation at Break

12%
18%

Reduction in Area

33%
40%

Shear Strength

400 MPa58 ksi
360 MPa52.2 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
290 MPa42.1 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

187 HB
170 HB

Hardness, Rockwell B

90 HRB
86 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,416°C2,581 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
65%

Weldability

30 / 100
32 / 100

Formability (cold)

35 / 100
45 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 35 L/kg4.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1145

1145-CD vs 1145-HR — frequently asked

Is 1145-CD stronger than 1145-HR?

Yes. 1145-CD has a typical yield strength of 565 MPa (81.9 ksi) against 325 MPa (47.1 ksi) for 1145-HR — about 74% more. Tensile strength is 655 MPa (95 ksi) vs 585 MPa (84.8 ksi).

Which condition does FabDigit quote by default, CD or HR?

CD is the default 1145 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1145-CD over 1145-HR?

Pick 1145-CD when strength drives the design. Pick 1145-HR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1145-CD and 1145-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.