Steel · 1145 temper comparison

1145-A and 1145-CD are two conditions of the same steel grade, 1145: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1145-CD is the stronger of the two: yield strength 565 MPa (81.9 ksi) against 310 MPa (45 ksi) for 1145-A, about 82% more; tensile strength follows at 655 MPa (95 ksi) vs 570 MPa (82.7 ksi). In exchange, 1145-A is the more ductile: elongation 22% versus 12% for 1145-CD, and 1145-CD is harder (187 HB vs 163 HB).

1145-AChoose it when the part is bent, formed or impact-loaded.

1145-CDChoose it when strength drives the design.

1145-A vs 1145-CD: properties

1145-A1145-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
565 MPa81.9 ksi

Elongation at Break

22%
12%

Reduction in Area

45%
33%

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
330 MPa47.9 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

163 HB
187 HB

Hardness, Rockwell B

84 HRB
90 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 400 MPa58 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,416°C2,581 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
70%

Weldability

35 / 100
30 / 100

Formability (cold)

55 / 100
35 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 35 L/kg4.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1145

1145-A vs 1145-CD — frequently asked

Is 1145-CD stronger than 1145-A?

Yes. 1145-CD has a typical yield strength of 565 MPa (81.9 ksi) against 310 MPa (45 ksi) for 1145-A — about 82% more. Tensile strength is 655 MPa (95 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, A or CD?

CD is the default 1145 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1145-A or 1145-CD?

1145-CD, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 1145-A; for welding the order is 1145-A first (fair, 35/100) then 1145-CD (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1145-A and 1145-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.