FabDigitFabDigit

Steel 1141-CD vs 1141 Normalized

Steel · 1141 temper comparison

1141-CD and 1141 Normalized are two conditions of the same steel grade, 1141: CD (cold drawn) versus Normalized. The chemistry is identical, so every difference below comes from the condition. 1141-CD is the stronger of the two: yield strength 640 MPa (92.8 ksi) against 405 MPa (58.7 ksi) for 1141 Normalized, about 58% more; tensile strength follows at 765 MPa (111 ksi) vs 706 MPa (102 ksi). In exchange, 1141 Normalized is the more ductile: elongation 22.7% versus 10% for 1141-CD, and 1141-CD is harder (217 HB vs 201 HB).

1141-CDChoose it when strength drives the design.

1141 NormalizedChoose it when the part is bent, formed or impact-loaded.

1141-CD vs 1141 Normalized: properties

1141-CD1141 Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

765 MPa111 ksi
706 MPa102 ksi

Yield Strength (0.2% offset)

640 MPa92.8 ksi
405 MPa58.7 ksi

Elongation at Break

10%
22.7%

Reduction in Area

35%
56%

Shear Strength

460 MPa66.7 ksi
425 MPa61.6 ksi

Fatigue Strength (Endurance Limit)

345 MPa50 ksi
315 MPa45.7 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
52 J38.4 ft·lbf

Hardness, Brinell

217 HB
201 HB

Hardness, Rockwell B

96 HRB
93 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
70%

Formability (cold)

25 / 100
33 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 55 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1141

1141-CD vs 1141 Normalized — frequently asked

Is 1141-CD stronger than 1141 Normalized?

Yes. 1141-CD has a typical yield strength of 640 MPa (92.8 ksi) against 405 MPa (58.7 ksi) for 1141 Normalized — about 58% more. Tensile strength is 765 MPa (111 ksi) vs 706 MPa (102 ksi).

Which condition does FabDigit quote by default, CD or Normalized?

HR is the default 1141 condition in the FabDigit quote flow (neither CD nor Normalized). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1141-CD over 1141 Normalized?

Pick 1141-CD when strength drives the design. Pick 1141 Normalized when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1141-CD and 1141 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.