FabDigitFabDigit

Steel 1120-A vs 1120-N

Steel · 1120 temper comparison

1120-A and 1120-N are two conditions of the same steel grade, 1120: A (solution annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1120-N is the stronger of the two: yield strength 255 MPa (37 ksi) against 220 MPa (31.9 ksi) for 1120-A, about 16% more; tensile strength follows at 450 MPa (65.3 ksi) vs 395 MPa (57.3 ksi). In exchange, 1120-A is the more ductile: elongation 30% versus 27% for 1120-N, and 1120-N is harder (131 HB vs 111 HB).

1120-AChoose it when the part is bent, formed or impact-loaded.

1120-NChoose it when strength drives the design.

1120-A vs 1120-N: properties

1120-A1120-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

220 MPa31.9 ksi
255 MPa37 ksi

Elongation at Break

30%
27%

Reduction in Area

55%
52%

Shear Strength

265 MPa38.4 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
205 MPa29.7 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
75 MPa·√m68.3 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

111 HB
131 HB

Hardness, Rockwell B

62 HRB
73 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51.9 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.5 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
74 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
78%

Weldability

48 / 100
45 / 100

Formability (cold)

60 / 100
52 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1120

1120-A vs 1120-N — frequently asked

Is 1120-N stronger than 1120-A?

Yes. 1120-N has a typical yield strength of 255 MPa (37 ksi) against 220 MPa (31.9 ksi) for 1120-A — about 16% more. Tensile strength is 450 MPa (65.3 ksi) vs 395 MPa (57.3 ksi).

Which condition does FabDigit quote by default, A or N?

CD is the default 1120 condition in the FabDigit quote flow (neither A nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1120-A or 1120-N?

1120-N. Its machinability rates very good (74/100) against good (68/100) for 1120-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1120-A and 1120-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.