FabDigitFabDigit

Steel 1120-A vs 1120-HR

Steel · 1120 temper comparison

1120-A and 1120-HR are two conditions of the same steel grade, 1120: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1120-HR is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 220 MPa (31.9 ksi) for 1120-A, about 9% more; tensile strength follows at 435 MPa (63.1 ksi) vs 395 MPa (57.3 ksi). In exchange, 1120-A is the more ductile: elongation 30% versus 26% for 1120-HR, and 1120-HR is harder (126 HB vs 111 HB).

1120-AChoose it when the part is bent, formed or impact-loaded.

1120-HRChoose it when strength drives the design.

1120-A vs 1120-HR: properties

1120-A1120-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
435 MPa63.1 ksi

Yield Strength (0.2% offset)

220 MPa31.9 ksi
240 MPa34.8 ksi

Elongation at Break

30%
26%

Reduction in Area

55%
50%

Shear Strength

265 MPa38.4 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
200 MPa29 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

111 HB
126 HB

Hardness, Rockwell B

62 HRB
71 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51.9 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.5 % IACS

Same in both: Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
75%

Weldability

48 / 100
45 / 100

Formability (cold)

60 / 100
55 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1120

1120-A vs 1120-HR — frequently asked

Is 1120-HR stronger than 1120-A?

Yes. 1120-HR has a typical yield strength of 240 MPa (34.8 ksi) against 220 MPa (31.9 ksi) for 1120-A — about 9% more. Tensile strength is 435 MPa (63.1 ksi) vs 395 MPa (57.3 ksi).

Which condition does FabDigit quote by default, A or HR?

CD is the default 1120 condition in the FabDigit quote flow (neither A nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1120-A over 1120-HR?

Pick 1120-A when the part is bent, formed or impact-loaded. Pick 1120-HR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1120-A and 1120-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.