FabDigitFabDigit

Steel 1113-CD vs 1113-HR

Steel · 1113 temper comparison

1113-CD and 1113-HR are two conditions of the same steel grade, 1113: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1113-CD is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 235 MPa (34.1 ksi) for 1113-HR, about 77% more; tensile strength follows at 495 MPa (71.8 ksi) vs 425 MPa (61.6 ksi). In exchange, 1113-HR is the more ductile: elongation 25% versus 10% for 1113-CD, and 1113-CD is harder (170 HB vs 121 HB).

1113-CDChoose it when strength drives the design.

1113-HRChoose it when the part is bent, formed or impact-loaded.

1113-CD vs 1113-HR: properties

1113-CD1113-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

495 MPa71.8 ksi
425 MPa61.6 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
235 MPa34.1 ksi

Elongation at Break

10%
25%

Reduction in Area

35%
45%

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
190 MPa27.6 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

170 HB
121 HB

Hardness, Rockwell B

87 HRB
69 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.29 · Shear Strength 300 MPa43.5 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

92 / 100
86 / 100

Machinability Rating (AISI 1212 = 100 %)

135%
125%

Formability (cold)

25 / 100
35 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 45 / 100 · Polishability 35 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1113

1113-CD vs 1113-HR — frequently asked

Is 1113-CD stronger than 1113-HR?

Yes. 1113-CD has a typical yield strength of 415 MPa (60.2 ksi) against 235 MPa (34.1 ksi) for 1113-HR — about 77% more. Tensile strength is 495 MPa (71.8 ksi) vs 425 MPa (61.6 ksi).

Which condition does FabDigit quote by default, CD or HR?

CD is the default 1113 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1113-CD or 1113-HR?

1113-CD, by a small margin. Both rate excellent for machinability — 92/100 against 86/100 for 1113-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1113-CD and 1113-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.