FabDigitFabDigit

Steel 1109-CD vs 1109-HR

Steel · 1109 temper comparison

1109-CD and 1109-HR are two conditions of the same steel grade, 1109: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1109-CD is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 235 MPa (34.1 ksi) for 1109-HR, about 77% more; tensile strength follows at 470 MPa (68.2 ksi) vs 420 MPa (60.9 ksi). In exchange, 1109-HR is the more ductile: elongation 25% versus 15% for 1109-CD, and 1109-CD is harder (137 HB vs 121 HB).

1109-CDChoose it when strength drives the design.

1109-HRChoose it when the part is bent, formed or impact-loaded.

1109-CD vs 1109-HR: properties

1109-CD1109-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
235 MPa34.1 ksi

Elongation at Break

15%
25%

Reduction in Area

40%
45%

Shear Strength

320 MPa46.4 ksi
275 MPa39.9 ksi

Fatigue Strength (Endurance Limit)

220 MPa31.9 ksi
190 MPa27.6 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

137 HB
121 HB

Hardness, Rockwell B

75 HRB
67 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 9 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
80%

Formability (cold)

55 / 100
68 / 100

Same in both: Weldability 40 / 100 · Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1109

1109-CD vs 1109-HR — frequently asked

Is 1109-CD stronger than 1109-HR?

Yes. 1109-CD has a typical yield strength of 415 MPa (60.2 ksi) against 235 MPa (34.1 ksi) for 1109-HR — about 77% more. Tensile strength is 470 MPa (68.2 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, CD or HR?

CD is the default 1109 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1109-CD over 1109-HR?

Pick 1109-CD when strength drives the design. Pick 1109-HR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1109-CD and 1109-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.