FabDigitFabDigit

Steel 1109-A vs 1109-N

Steel · 1109 temper comparison

1109-A and 1109-N are two conditions of the same steel grade, 1109: A (solution annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1109-N is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 225 MPa (32.6 ksi) for 1109-A, about 11% more; tensile strength follows at 405 MPa (58.7 ksi) vs 370 MPa (53.7 ksi). 1109-N is harder — 116 HB against 105 HB for 1109-A — which matters for wear surfaces and threads.

1109-NChoose it when strength drives the design, or when surface hardness matters.

1109-A vs 1109-N: properties

1109-A1109-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

370 MPa53.7 ksi
405 MPa58.7 ksi

Yield Strength (0.2% offset)

225 MPa32.6 ksi
250 MPa36.3 ksi

Elongation at Break

30%
28%

Reduction in Area

55%
52%

Shear Strength

320 MPa46.4 ksi
270 MPa39.2 ksi

Fatigue Strength (Endurance Limit)

220 MPa31.9 ksi
195 MPa28.3 ksi

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

105 HB
116 HB

Hardness, Rockwell B

58 HRB
65 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51.9 W/m·K30 BTU/hr·ft·°F
52 W/m·K30 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
11.2 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.54×10⁻⁷ Ω·m6.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 9 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
78%

Weldability

40 / 100
45 / 100

Formability (cold)

75 / 100
72 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1109

1109-A vs 1109-N — frequently asked

Is 1109-N stronger than 1109-A?

Yes. 1109-N has a typical yield strength of 250 MPa (36.3 ksi) against 225 MPa (32.6 ksi) for 1109-A — about 11% more. Tensile strength is 405 MPa (58.7 ksi) vs 370 MPa (53.7 ksi).

Which condition does FabDigit quote by default, A or N?

CD is the default 1109 condition in the FabDigit quote flow (neither A nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1109-A or 1109-N?

1109-N. Its weldability rates fair (45/100) against fair (40/100) for 1109-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1109-A and 1109-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.