Steel · 1108 temper comparison

1108-CD and 1108-N are two conditions of the same steel grade, 1108: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1108-CD is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 215 MPa (31.2 ksi) for 1108-N, about 53% more; tensile strength follows at 385 MPa (55.8 ksi) vs 360 MPa (52.2 ksi). In exchange, 1108-N is the more ductile: elongation 30% versus 20% for 1108-CD, and 1108-CD is harder (111 HB vs 100 HB).

1108-CDChoose it when strength drives the design.

1108-NChoose it when the part is bent, formed or impact-loaded.

1108-CD vs 1108-N: properties

1108-CD1108-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

385 MPa55.8 ksi
360 MPa52.2 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
215 MPa31.2 ksi

Elongation at Break

20%
30%

Reduction in Area

40%
55%

Compressive Strength

330 MPa47.9 ksi
215 MPa31.2 ksi

Shear Strength

250 MPa36.3 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
180 MPa26.1 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

111 HB
100 HB

Hardness, Rockwell B

64 HRB
56 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 472 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.64×10⁻⁷ Ω·m6.46 µΩ·in

Same in both: Electrical Conductivity 10.5 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
71 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
72%

Weldability

50 / 100
52 / 100

Formability (cold)

50 / 100
65 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 65 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1108

1108-CD vs 1108-N — frequently asked

Is 1108-CD stronger than 1108-N?

Yes. 1108-CD has a typical yield strength of 330 MPa (47.9 ksi) against 215 MPa (31.2 ksi) for 1108-N — about 53% more. Tensile strength is 385 MPa (55.8 ksi) vs 360 MPa (52.2 ksi).

Which condition does FabDigit quote by default, CD or N?

CD is the default 1108 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1108-CD or 1108-N?

1108-CD, by a small margin. Both rate very good for machinability — 78/100 against 71/100 for 1108-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1108-CD and 1108-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.