FabDigitFabDigit

Steel 10G2S1-A vs 10G2S1-QT

Steel · 10G2S1 temper comparison

10G2S1-A and 10G2S1-QT are two conditions of the same steel grade, 10G2S1: A (solution annealed) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 10G2S1-QT is the stronger of the two: yield strength 440 MPa (63.8 ksi) against 305 MPa (44.2 ksi) for 10G2S1-A, about 44% more; tensile strength follows at 600 MPa (87 ksi) vs 460 MPa (66.7 ksi). In exchange, 10G2S1-A is the more ductile: elongation 28% versus 19% for 10G2S1-QT, and 10G2S1-QT is harder (200 HB vs 143 HB). On the shop floor, 10G2S1-A welds better (80 vs 70 out of 100).

10G2S1-AChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

10G2S1-QTChoose it when strength drives the design.

10G2S1-A vs 10G2S1-QT: properties

10G2S1-A10G2S1-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

460 MPa66.7 ksi
600 MPa87 ksi

Yield Strength (0.2% offset)

305 MPa44.2 ksi
440 MPa63.8 ksi

Elongation at Break

28%
19%

Reduction in Area

58%
52%

Compressive Strength

305 MPa44.2 ksi
360 MPa52.2 ksi

Shear Strength

280 MPa40.6 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

205 MPa29.7 ksi
275 MPa39.9 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
85 J62.7 ft·lbf

Hardness, Brinell

143 HB
200 HB

Hardness, Rockwell B

77 HRB
84 HRB

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.9 % IACS
6.6 % IACS

Electrical Resistivity

2.5×10⁻⁷ Ω·m9.84 µΩ·in
2.6×10⁻⁷ Ω·m10.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 14 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
50%

Weldability

80 / 100
70 / 100

Formability (cold)

72 / 100
50 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale10G2S1

10G2S1-A vs 10G2S1-QT — frequently asked

Is 10G2S1-QT stronger than 10G2S1-A?

Yes. 10G2S1-QT has a typical yield strength of 440 MPa (63.8 ksi) against 305 MPa (44.2 ksi) for 10G2S1-A — about 44% more. Tensile strength is 600 MPa (87 ksi) vs 460 MPa (66.7 ksi).

Which condition does FabDigit quote by default, A or QT?

HR is the default 10G2S1 condition in the FabDigit quote flow (neither A nor QT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 10G2S1-A or 10G2S1-QT?

10G2S1-A, by a small margin. Both rate good for machinability — 60/100 against 55/100 for 10G2S1-QT; for welding the order is 10G2S1-A first (very good, 80/100) then 10G2S1-QT (very good, 70/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 10G2S1-A and 10G2S1-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.